Installing a Remote Control Enclosure

WARNING
ELECTRIC SHOCK HAZARD:
• Remote control enclosure must be mounted on vertical
wall and installed in vertical position. Mounting remote
control enclosure in horizontal position may result in
collection of liquids and lead to electric shock.
• Operating voltage of remote control enclosure water valve
exceeds 50 V (extra low voltage). Enclosure is marked
with the following hazard identification symbol:
NOTE: A qualified electrician should connect the unit(s) to a
power source. A qualified plumber should connect the
water supply and drain(s).
NOTE: Refer to the Installing an Auto-Fill Unit before installing
a Remote Control Enclosure.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Enclosure Cutout Dimensions" chart
for the cutout dimensions for each control enclosure.
• The cutout depth required for all control enclosures is
5" (127 mm).
• Make sure to have enough space inside the cutout if
installing with conduit on the side of the control enclosure.
• For units with two control enclosures: If the unit is
equipped with Auto-Fill, each enclosure cutout size will
be different (see chart).
Model and Enclosure
HWBI-S2
Control w/o Auto-Fill
Control w/ Auto-Fill
HWBI-S3
Control w/o Auto-Fill
Control w/ Auto-Fill
HWBI-S4
Left Control w/o Auto-Fill
Left Control w/ Auto-Fill
Right Control
Single Enclosure w/o Auto-Fill *
Single Enclosure w/ Auto-Fill *
* HWBI-S4 Series units with all controls in a single control enclosure — required for Canadian units.
A
B
C

Control Enclosure Cutout Dimensions

Opening Dimensions
(A)
8" (203 mm)
12-3/8" (314 mm)
10-1/4" (260 mm)
14-5/8" (371 mm)
8" (203 mm)
12-3/8" (314 mm)
8" (203 mm)
12-1/2" (318 mm)
16-7/8" (429 mm)
D
Front View –
Control Enclosure
Control Enclosure Cutout Dimensions
IMPORTANT NOTE:
Install the control enclosure on the front of the unit to ensure
the controls correspond with the correct wells. The front of the
unit is the side the conduit(s) enters under the unit.
2. Remove the trim cover from the control enclosure.
3. Position the control enclosure into the opening through the
backside.
4. Secure the control enclosure to the mounting surface
using screws (#8 sheet metal screw supplied).
5. Connect the proper power
source to the mounted
remote control enclosure.
Wiring must be fixed a
minimum of 4" (102 mm)
from bottom of well(s).
6. Connect the water supply to
the optional Auto-Fill system,
if equipped. Refer to the
"Side Mounted Auto-Fill" or
"Drain Mounted Auto-Fill"
procedure in the OPTIONS AND ACCESSORIES section.
7. Reinstall the trim cover. Seal the trim cover to the
mounting surface with silicone adhesive
NOTE: Standard UL approved units are equipped with 72"
(1829 mm) flexible conduit connected to the remote
control enclosure.
(B)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
12-11/16" (321 mm)
4-3/4" (121 mm)
10-9/16" (268 mm)
4-3/4" (121 mm)
14-15/16" (379 mm)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
12-11/16" (321 mm)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
12-13/16" (324 mm)
4-3/4" (121 mm)
17-3/16" (436 mm)
1-7/8"
2-11/16"
(48 mm)
(68 mm)
Side View –
Control Enclosure
10
English
HWBI-S3 Control
Enclosure
Power
"In"
Screw Hole Dimensions
(C)
(D)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
IMPORTANT NOTE:
Make sure the installation
1-1/8"
location provides enough
(29 mm)
room for electrical and
plumbing connections to the
control enclosure. Follow
local and national plumbing
and electrical codes.