6. Attach the fourth mounting bracket assembly to the
underside of the countertop at the open corner of the cold
shelf.
7. Adjust the leveling bolts underneath each corner of the
unit so that the shelf is flush against the underside of the
countertop.
8. Tighten the lock nut on each leveling bolt to secure the
position.
9. Apply polyurethane-based foam sealant in the gap
between the countertop and the cold shelf.
Seal this gap with foam sealant
underneath the entire unit.
Foam Sealant Gap

Installing the Control Enclosure Remotely

Use the following procedure to install the control enclosure
remotely within 4' (1219 mm) of the condensing unit.
WARNING
Control enclosure must be mounted in a vertical surface.
Mounting control enclosure in a horizontal surface may
result in the collection of liquids and lead to electric shock.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Panel Cutout and Screw Hole
Dimensions" chart for the cutout dimensions.
Mounting Bracket
Assembly
Lock Nut
Leveling Bolt
Installing a CSU Model Cold Shelf
2. Remove the four trim cover screws from the control panel
and remove the trim cover.
3. Position the control panel into the cutout opening through
the backside.
4. Fasten the control panel to the vertical surface using four
screws (not supplied).
5. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the "Control Panel Cutout and Screw Hole Dimensions"
illustration for more information.
6. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
7/16"
(11 mm)
3/8"
(9 mm)
Control Panel Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control panel cutout does
not exceed the above dimension.
18
English
Silicone Sealant
1-1/16"
(27 mm)
5-5/8"
(143 mm)
3-1/2"
(89 mm)
7-7/16"
(189 mm)
7-3/4"
(196 mm)
Underside of
Countertop
Form No. CSM-0417

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Csbf-48-sCsu-48-sCssb-4818Cssbf-48-s

Table des Matières