INSTALLATION

Installing a Top Mounted Unit (CSBF Models)

NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Lift the unit out of the shipping frame and carefully lower it
into the countertop cutout.This step requires two or more
people, depending on the unit.
2. Apply a bead of National Sanitation Foundation (NSF)-
approved silicone sealant on the top edge of the countertop
cutout and the underside of the trim mounting ring. The
sealant must be rated for use at temperatures between
-10°F (-23°C) and 250°F (121°C).
IMPORTANT NOTE
The condensing unit is shipped "loose" from the cold shelf.
They are attached only by the flexible tubing that connects
the condensing unit to the evaporator coil in the cold shelf.
Use caution during installation and avoid putting strain on the
flexible tubing.
3. Lift the cold shelf followed by the condensing unit out of the
wooden shipping frame and carefully lower them into the
countertop cutout. This step requires two or more people.
• The condensing unit must go into the cutout first and
be fastened to a level, stable surface within 4' (1219
mm) of the connections on the bottom of the cold shelf.
Refer to the SPECIFICATIONS section for installation
dimensions.
4. Install the control panel in the desired location, if installing
remotely.
• The control enclosure can be installed remotely within
4' (1219 mm) of the condensing unit. Refer to the
"Installing the Control Enclosure Remotely" procedure
in this section.
Countertop Cutout Dimensions — CSBF Models
Model
Width (A)
24-5/8" to 25"
CSBF-24-F
(625 to 635 mm)
24-5/8" to 25"
CSBF-24-I
(625 to 635 mm)
24-5/8" to 25"
CSBF-24-S
(625 to 635 mm)
36-5/8" to 37"
CSBF-36-F
(930 to 940 mm)
36-5/8" to 37"
CSBF-36-I
(930 to 940 mm)
36-5/8" to 37"
CSBF-36-S
(930 to 940 mm)
48-5/8" to 49"
CSBF-48-F
(1234 to 1245 mm)
48-5/8" to 49"
CSBF-48-I
(1234 to 1245 mm)
48-5/8" to 49"
CSBF-48-S
(1234 to 1245 mm)
DO NOT tip unit/mounting surface after final installation.
Unit is free-floating and could fall out if tipped—for
permanent, horizontal installations only.
Condensing
Depth (B)
16-1/8" to 16-1/2"
(409 to 419 mm)
20-1/8" to 20-1/2"
(511 to 521 mm)
24-5/8" to 25"
(625 to 635 mm)
16-1/8" to 16-1/2"
(409 to 419 mm)
20-1/8" to 20-1/2"
(511 to 521 mm)
24-5/8" to 25"
(625 to 635 mm)
16-1/8" to 16-1/2"
(409 to 419 mm)
20-1/8" to 20-1/2"
(511 to 521 mm)
24-5/8" to 25"
(625 to 635 mm)
14
CAUTION
5. Clean the cold surface thoroughly in preparation for initial
operation. Refer to the MAINTENANCE section for proper
cleaning procedures.
6. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
unit enters
countertop
cutout first.
l o w
A i r F
Ventilation/Control
Access Openings
(on both sides
of cabinet)
Installing a CSBF Model Cold Shelf
English
Condenser coils
on back of
condensing unit.
Countertop
Cutout
B