Installing an Auto-Fill Unit

The side mounted Auto-Fill option connects the on-site water
supply through the control panel to an Auto-Fill fitting on the
side of the well enclosure. Use the following procedure to install
a unit equipped with the side mounted Auto-Fill option.
Auto-Fill units must be installed with adequate backflow
protection and must conform with federal, state, and local codes.
NOTICE
Auto-fill units supplied with water from a reverse osmosis
(RO) system (or similiar water filtration system) must be
installed with an operating reminerialization sytem to
ensure proper operation. Failure to do so may cause unit
to overfill. Damage caused by overfilling is not covered
under warranty.
Drain sealants must have temperature rating of 500°F or
higher. Incoming water pipes must be FDA compliant for
potable water.
1. Connect the street elbow to the Auto-Fill fitting located on
the outside of the well. Replace the fill tube hose on fitting.
NOTE: The fill tube hose may need to be removed from the fill
tube assembly for ease of installation.
2. Connect the fill tube hose to the fill valve nipple in the control
enclosure and secure using the hose clamp. (Disassemble
the control enclosure trim cover to access the nipple.)
3. Connect the on-site water supply line to the 1/4" NPT
water inlet fitting on the control enclosure.
4. Turn on the water supply and check for leaks.
Fill Tube
Assembly
Water Inlet Fitting
Fill Valve Nipple
Hose Clamp
Installing a Side Mounted Auto-Fill Unit (HWBIB-FULDA shown)
NOTE: Refer to "Water Supply Specifications" in the
SPECIFICATIONS section of this manual for water
supply requirements.

Installing A Drain Assembly

After installing a drain-equipped unit into the countertop, use the
following procedure to connect the unit to the on-site drain line.
NOTE: Consult a licensed plumbing contractor for proper drain
installation that conforms to local plumbing codes.
NOTE: Approved air gap or other back-flow prevention device
must be installed by a licensed plumber, if required.
Form No. HWBM-0518
CAUTION
Auto-Fill Fitting
Street Elbow
Water Inlet Fitting
Fill Tube
BURN HAZARD: Drain water may reach temperatures
in excess of 200°F (93°C). Use appropriate plumbing
materials when installing drain.
1. Connect drain pipe (supplied by others) from the 3/4" NPT
drain fitting on the bottom of the unit to a 3/4" drain valve
(available as an accessory from Hatco).
NOTE: The drain valve must be installed in an easily accessible
location for the operator.
2. Connect the drain valve to the on-site drain line (not supplied).
NOTE: Hatco recommends using a union fitting with the drain
assembly for ease of servicing.
3/4" Drain Fitting

Installing a Bottom Mount Unit

Installation of a bottom mount unit requires custom fabrication of
the countertop by a qualified and experienced installer. Use the
following information as guidelines for one method of installing a
bottom mount unit. Refer to the OPTIONS AND ACCESSORIES
section for installation with an optional mounting bracket.
• Create the countertop cutout with turned-down flanges on
all four sides. These flanges should be positioned on the
inside of the well for installation.
Front View
Turned-Down Flange
8-3/4"
(222 mm)
12-1/32"
(306 mm)
Side View
Turned-Down Flange
16-3/4" (426 mm)
20-1/32" (509 mm)
Suggested Turned-Down Flange Dimensions
• Apply silicone sealant to the top edge of the well before
installation.
• Secure the unit to the countertop by installing mounting
screws (not supplied) through the turned-down flanges
and into the top rim of the well.
Turned-Down
Flanges
Installing Bottom Mount Unit
21
INSTALLATION
CAUTION
3/4" Drain Valve
Drain Connection
Countertop
Countertop
Countertop
Mounting Screw
(not supplied)
To drain
1-3/32"
(28 mm)

Publicité