INSTALLATION
Installing a Top Mounted Unit (HCSBF Series)
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. apply a bead of National Sanitation Foundation (NSF)-
approved silicone sealant on the top edge of the
countertop cutout and the underside of the trim mounting
ring. The sealant must be rated for use at temperatures
between -10°F (-23°C) and 250°F (121°C).
IMPORTANT NOTE
The condensing unit is shipped "loose" from the hot/cold shelf.
They are attached only by the flexible tubing that connects
the condensing unit to the evaporator coil in the hot/cold shelf.
Use caution during installation and avoid putting strain on the
flexible tubing.
2. Lift the hot/cold shelf followed by the condensing unit out of
the wooden shipping frame and carefully lower them into the
countertop cutout. This step requires two or more people.
• The condensing unit must go into the cutout first and be
fastened to a level, stable surface within 4' (1219 mm)
of the connections on the bottom of the hot/cold shelf.
Refer to the SPECIFICaTIONS section for installation
dimensions.
3. Install the control panel in the desired location, if installing
remotely.
• The control enclosure can be installed remotely within 4'
(1219 mm) of the condensing unit. Refer to the
"Installing the Control Enclosure Remotely" procedure in
this section.
Countertop Cutout Dimensions — HCSBF Models
Model
Width (A)
24-5/8" to 25"
HCSBF-24-F
(625 to 635 mm)
24-5/8" to 25"
HCSBF-24-I
(625 to 635 mm)
24-5/8" to 25"
HCSBF-24-S
(625 to 635 mm)
36-5/8" to 37"
HCSBF-36-F
(930 to 940 mm)
36-5/8" to 37"
HCSBF-36-I
(930 to 940 mm)
DO NOT tip unit/mounting surface after final installation.
Unit is free-floating and could fall out if tipped—for
permanent, horizontal installations only.
4. Clean the hot/cold surface thoroughly in preparation for
5. Plug the unit into a properly grounded electrical receptacle
Condensing
Depth (B)
16-1/8" to 16-1/2"
HCSBF-36-S
(409 to 419 mm)
20-1/8" to 20-1/2"
HCSBF-48-F
(511 to 521 mm)
24-5/8" to 25"
(625 to 635 mm)
16-1/8" to 16-1/2"
HCSBF-48-S
(409 to 419 mm)
20-1/8" to 20-1/2"
(511 to 521 mm)
A
12
CAUTION
initial operation. Refer to the maINTENaNCE section for
proper cleaning procedures.
of the correct voltage, size, and plug configuration. See the
SPECIFICaTIONS section for details.
unit enters
countertop
cutout first.
l o w
l o w
A i r F
A i r F
Ventilation/Control
Access Openings
(on both sides
of cabinet)
Installing a HCSBF Series Hot/Cold Shelf
Model
Width (A)
36-5/8" to 37"
(930 to 940 mm)
48-5/8" to 49"
(1234 to 1245 mm)
48-5/8" to 49"
HCSBF-48-I
(1234 to 1245 mm)
48-5/8" to 49"
(1234 to 1245 mm)
B
English
Condenser coils
on back of
condensing unit.
Countertop
Cutout
Depth (B)
24-5/8" to 25"
(625 to 635 mm)
16-1/8" to 16-1/2"
(409 to 419 mm)
20-1/8" to 20-1/2"
(511 to 521 mm)
24-5/8" to 25"
(625 to 635 mm)
Form No. HCSm-0416

Publicité

Chapitres

Table des Matières
loading

Table des Matières