General

Hot/Cold Built-In Shelves are shipped from the factory completely
assembled and ready for use. Use the following information and
procedures to prepare the unit and the installation site.
NOTE: Make sure the installation location provides enough
room for the condensing unit and the remote mounted
control enclosure.
WARNING
ELECTRIC SHOCK HAzARD:
• Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
• Unit is not weatherproof. Locate unit indoors.
• Remote control enclosure must be mounted on vertical
wall and installed in vertical position. Mounting remote
control enclosure in horizontal position may result in
collection of liquids and lead to electric shock.
FIRE HAzARD: Install condensing unit with a minimum of
6" (152 mm) of space between all sides of unit and any
combustible surfaces.
CAUTION
Locate unit at proper counter height in an area that is
convenient for use. The location should be strong enough
to support the weight of unit and contents.
NOTICE
Transport and install unit in upright position only. Failure
to do so may result in damage to refrigeration system.
This unit is designed for use in environments where ambient
temperature is between 65°F (18°C) and 86°F (30°C).
When shipped during cold weather months, store unit for
at least 10 hours in an environment where ambient
temperature is between 65°F (18°C) and 86°F (30°C) to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warmup time.
Provide louvered or grill-style openings with a minimum
size of 12" x 12"/144 square inches (31 x 31 cm/
961 square cm) in the cabinetry in front of and behind the
condensing unit for proper ventilation. Failure to provide
adequate air flow through the condensing unit may cause
unit failure and will void the unit warranty.
Do not recirculate exhaust air inside cabinet when multiple
condensing units are installed together. Intake air should
enter from outside of cabinet.
Do not locate unit in area with excessive air movement
around unit. Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods, air
conditioning ducts, and exterior doors).
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Damage to any countertop material caused by heat or cold
generated from Hatco equipment is not covered under the
Hatco warranty. Contact manufacturer of countertop
material for application information.
Form No. HCSm-0416
all Hot/Cold Built-In Shelves are shipped in a wooden frame for
protection and stability. Keep the unit in the wooden frame until
the unit and the installation site are completely prepared for the
unit to be installed.
Survey the installation site. Take into account the need for
louvered or grill-style openings in the cabinetry to provide proper
ventilation for the condensing unit as well as access to the
control panel. One of these ventilation openings must be in front
of the condensing coils with the other on the opposite side. If
multiple condensing units are installed in the same counter, each
unit should intake cool air and expel hot air.
1. Remove all external packaging from the unit.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPORTaNT OWNER INFORmaTION section for
details.
2. Remove tape, protective packaging, and literature from all
surfaces of the unit.

Preparing the Installation Site

1. Prepare the appropriate opening in the countertop for the
unit being installed.
• For top mounted HCSBF models, refer to the
"Countertop Cutout Dimensions — HCSBF models," in
this section.
• For bottom mounted HCSSB and HCSSBF models,
refer to the "Countertop Cutout and mounting Bolt
Dimensions — HCSSB and HCSSBF models," in this
section.
2. If installing the control enclosure remotely, cut and drill the
appropriate holes in the vertical surface where the control
enclosure will be installed. Refer to the "Installing the
Control Enclosure Remotely" procedure for cutout
dimensions.
• The installation depth required for the control enclosure
is 8-1/2" (216 mm).
3. make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents.
4. make sure the following cabinet interior specifications and
clearances are available:
• a level, stable surface for mounting the condensing unit
within 4' (1219 mm) of the connections on the bottom of
the hot/cold shelf. Refer to the SPECIFICaTIONS
section for installation dimensions.
• a minimum 2" (51 mm) clearance between the
condensing unit and any combustible surface.
5. Cut two openings in the cabinetry to provide proper
ventilation to the condensing unit as well as access to the
control panel. Louvered or grill-style panels should be
installed in the openings to protect the condensing unit.
• Openings should be a minimum of 12" x 12" (31 x 31 cm)
or 144 square inches (961 square cm).
• One opening should be located in front of the condenser
coils with the other opening on the opposite side.
6. Install the unit. Refer to the appropriate procedure in this
section for the model being installed.