INSTALLATION

Installing a Remote Mounted Control Box

WARNING
ELECTRIC SHOCK HAzARD: The remote mounted control
box must be mounted on a vertical wall and installed in the
vertical position. Mounting the control box in the horizontal
position may result in the collection of liquids and lead to
an electric shock.
NOTE: A qualified electrician is recommended for connecting
the unit to a power source. A qualified plumber is
recommended for connecting drain(s) and Auto-Fill.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Box Cutout Dimensions" below for the
cutout dimensions for each control box.
2. Remove the trim cover from the control box assembly.
3. Position the control box into the opening through the
backside.

Control Box Cutout Dimensions

Model
Control Box assembly
Without Bezel (standard)
Control Box assembly
With Bezel (standard)
Recessed Control Box
assembly (optional)
Control Box assembly
with auto-Fill (optional)
Control Panel
For UR Units
A
C
B
D
Control Box Without
Bezel (standard)
Control Box Assembly
C
With Auto-Fill (optional)
Opening Dimensions Screw Hole Dimensions
(A)
(B)
56 mm
86 mm
(2-3/16")
(3-3/8")
83 mm
95 mm
(3-1/4")
(3-3/4")
149 mm
162 mm
(5-7/8")
(6-3/8")
(6-13/16")
257 mm
121 mm
(10-1/8")
(4-3/4")
54 mm
86 mm
(2-1/8")
(3-3/8")
A
C
Control Box With
Bezel (standard)
A
B
D
Control Box assembly Cutout Dimensions
4. Secure the control box to the mounting surface using
screws (#8 sheet metal screws supplied).
5. Connect the proper power source to the mounted remote
control box.
• For corded units, plug power cord into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. See the SPECIFICaTIONS
section for details.
• For hardwired units, have a qualified electrician make
the appropriate electrical connections.
NOTE: Standard, UL approved hardwired units are equipped
with a 914 mm (36") flexible conduit connected to the
control box.
6. Connect the water supply to the optional auto-Fill system,
if equipped. Refer to the "Installing an auto-Fill Unit"
procedure in this section.
7. Reinstall the trim cover.
(C)
(D)
83 mm
64 mm
(3-1/4")
(2-1/2")
105 mm
---
(4-1/8")
---
173 mm
98 mm
(3-7/8")
64 mm
264 mm
(2-1/2")
(10-7/16")
89 mm
57 mm
(3-1/2")
(2-1/4")
B
C
Recessed Control
Box (optional)
IMPORTANT NOTE:
Make sure the installation location provides enough room
for electrical and plumbing connections to the control box.
18
Standard
Control Box
To
Unit
Power
"In"
Control Box
w/Auto-Fill
To
Power
Unit
"In"
Control Box Electrical Connections
A
B
Control Panel
For UR Units
D
Form No. HWBCEM1-0515
Recessed
Control Box
To
Unit
Power
"In"
A