General

Flav-R 2-Go
Locker Systems are shipped with most
®
components pre-assembled. Care should be taken when
unpacking the shipping carton to avoid damage to the unit and
components enclosed. Use the following procedures to install
countertop, floor mount, and built-in models.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAZARD: Do not use an extension cord. If power
cord is too short, contact a qualified electrician to
determine and install proper voltage and size electrical
receptacle near unit.
CAUTION
Locate unit at proper counter height in an area that is
convenient for use. Location should be level to prevent
unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
NOTICE
Do not locate unit in an area subject to ambient
temperatures above 100°F (38°C). Doing so will damage
unit and void warranty.
Unit must be level for self-closing doors to function properly.
Do not lay unit on its side in any direction. Damage to unit
could occur.
NOTE: Due to the size and weight of the unit, use the proper
number of people for installation based on the weight
of the unit.
1. Inspect the shipping container for obvious signs of
transit damage. If damaged, inform the freight company
immediately. CAUTION! Stop! Do not attempt to use a
damaged unit. Contact Hatco for assistance.
2. Cut and remove the shipping bands from around the
packaging.
3. Remove tape and protective packaging from all surfaces
of the unit.
4. Inspect the unit for freight damage such as dents on the
exterior or inside the lockers. If damaged, inform the
freight company immediately.
5. Use one of the following procedures to install the unit
depending on the model and installation type.

• Installing Countertop Models

• Installing Floor Mount Models

• Installing Built-In Models
Form No. F2GM-0820
Installing Countertop Models
1. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
2. Verify that the unit is level. The self-closing doors will not
work properly if unit is not level.
• The unit must be within 0.5° of level. Use shims to level
unit, if necessary.
3. Apply NSF-approved sealant around the edge of the unit
and the countertop.
4. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
Installing Floor Mount Models
Floor mount models are shipped with an installation template
and instructions to minimize moving the unit. Use the installation
template or this procedure to install a floor mount model.
Use extreme caution when moving and tipping unit during
installation. Size and weight of unit create significant tip
and pinch point hazards. Remain aware and keep clear of
unit/pinch points while tipping to avoid serious injury.
1. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
2. Remove the access panels on the bottom of each column
on the front and back of the unit by removing the screws.
3. Mark the location of at least two mounting locations on
each side of the unit.
NOTE: If there is not access to the base on the operator side
of the unit, then it must be secured to the wall on the
operator side. Use the "Wall Mount Bracket Installation"
procedure in the OPTIONS AND ACCESSORIES
section for installing the unit to a wall.
4. Move the unit away from the installation location.
5. Pre-drill the marked mounting locations.
• Use the appropriate anchors and fasteners based on the
installation material.
6. Move the unit back to the installation location and line up
mounting holes with pre-drilled holes.
7. Verify that the unit is level before securing to the floor. The
self-closing doors will not work properly if unit is not level.
• The unit must be within 0.5° of level. Use washers on
the floor fasteners to level unit, if necessary.
8. Secure the unit to the floor by using the appropriate
fasteners through the floor plate and into the floor.
• The obround mounting holes are 1/2" wide.
9

INSTALLATION