Error Messages; Error Message Guide; Troubleshooting Guide - Hatco Flav-R 2-Go F2G Série Manuel D'installation Et D'utilisation

Système de casiers
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Symptom
Unit does not operate (blank
touchscreen).
Locker door not locking.
Passcode is not working.
Locker is heating.
Locker is not heating.

Error Messages

The locker system will display errors in the following ways:
• When the unit is turned on.
• When
is pressed on the Select Lockers screen.
• When the "Errors" button is selected on the System Settings
screen.
• When a new error occurs during operation.
When an error mesage is displayed, touch OK or
acknowledge the error and return to normal operation.

Error Message Guide

Error Message
Locker Communication!
Temp Sensor Out of Range! Move Power I/O (on/off) switch to the O (off) position.
Display Communication!
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on "Find A Service Agent"; or contact the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
Form No. F2GM-0820
Probable Cause
Unit unplugged.
Power I/O (on/off) switch in O (Off) position.
Unit connected to incorrect power supply.
Locker system not leveled during installation.
Door/hinges are defective.
Incorrect passcode is entered.
Locker set to Heated setting.
Locker set to Ambient setting.
Locker's temperature sensor is defective.
Error message "Temp Sensor Out of Range!"
appears on touchscreen display.
Troubleshooting
Move Power I/O (on/off) switch to the O (off) position.
Wait 5 seconds and move the Power I/O to the I (on)
position.
Wait 5 seconds and move the Power I/O to the I (on)
position.
Move Power I/O (on/off) switch to the O (off) position.
Wait 5 seconds and move the Power I/O to the I (on)
position.
e-mail: support@hatcocorp.com

TROUBLESHOOTING GUIDE

ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Make sure unit is plugged in.
Move Power I/O (on/off) switch to the I (On) position.
Refer to SPECIFICATIONS section for unit electrical
specifications. Contact a qualified electrician to determine
and install proper voltage and size electrical receptacle.
Level the locker system.
Inspect that the door is making contact with the locker
magnet. If contact is not being made, then the door/hinges
need to be replaced.
Contact Authorized Service Agent or Hatco for assistance.
Refer to the "Change a Locker's Heated/Ambient Setting"
procedure in the OPERATION section.
Refer to the "Change a Locker's Heated/Ambient Setting"
procedure in the OPERATION section.
Reboot the unit by turning power switch of and on. If issue
continues, contact Authorized Service Agent or Hatco for
assistance.
Locker Communication!
The system cannot communicate to a specific locker. Turn
power off and on to reboot. If problem continues, call service.
Temp Sensor Out of Range!
The temperature sensor is malfunctioning in a specific locker.
Turn power off and on to reboot. If problem continues, call
service.
Display Communication!
to
The system cannot communicate to all lockers. Turn power off
and on to reboot. If problem continues, call service.
Contact Authorized Service Agent or Hatco for assistance.
The locker will not function until the unit is serviced.
All other lockers will function normally.
Contact Authorized Service Agent or Hatco for assistance.
The locker will not function as a heated locker, but
can be used as an ambient locker until the unit is
serviced.
All other lockers will function normally.
Contact Authorized Service Agent or Hatco for
assistance.
No lockers will function until the unit is serviced.
17
WARNING
Corrective Action
Corrective Action
(if Troubleshooting fails to fix)

Publicité

Chapitres

Table des Matières
loading

Table des Matières