Overwriting the master transmitter
1. Switch off the VC470-II power for 10 seconds, then switch it back on.
The VC470-II is ready to programme for 3 minutes.
Note
To ensure that the new master transmitter is programmed in the de-
sired VC470-II only, all other receivers which are connected to the
same power supply must be deactivated from the programming mode.
To do so, after switching back on the power supply, execute a control
or stop command using the transmitter for the given receivers.
2. Now press the programming button of the new master transmitter for 10 sec-
onds.
The curtain will "nod" to confirm.
The new master transmitter has been programmed and the old master transmit-
ter deleted.
Programming switching times
Note
This function is only possible for transmitters of the Becker Centronic
control range with memory function.
The VC470-II can store the switching time for an UP and DOWN movement.
This curtain movement is repeated every 24 hours in the sliding switch
position „".
The / position for the sliding switch is unimportant when programming the
switching time. All previously stored switching times are overwritten accordingly.
1. If necessary, adjust the curtain to the opposite end position.
2. Wait until the time at which the automatic control command is to be executed.
3. Press and hold the respective direction button at the desired time until the
tubular drive briefly stops after approx. 6 seconds and subsequently moves
on until reaching the end position.
4. Release the direction key.
The VC470-II has saved the current time for this direction of travel.