INSTRUCTIONS FOR INSTALLATION

Baffle

To ensure that the appliance
37
±0.5
32
±0.5
works satisfactorily,
26
±0.5
it will need to be adjusted
according to the
customer-specific pipe system.
38c-1083
±0.5
42
fig. 5
Adjusting the baffle.
The baffle plate is supplied separately and should be fitted
into the heater as indicated in fig. 6.
G20/G25
8 – 12 metres
vertical + roof duct
5 – 7 metres
vertical + roof duct
3 – 4 m.
vertical + roof duct
1 – 2 m.
vertical + roof duct
1 m. vertical +
wall duct
1 m. vertical +
1 – 3 m.
horizontal + wall duct
0.5 m. vertical +
2 m. horizontal +
wall duct
Baffle
fig. 6
Air inlet
Damper
baffle
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
Use the adjustment jig provided (fig. 5) to adjust the baffle
to the right size. Once it has been adjusted, fix the damper
in place with the socket-head screw.
See the table for adjustment specifications.
In some cases the air inlet baffle should be removed.
To do this: (fig. 7).
Take strip (1) and the vermiculite trays (2+3) out of the
appliance.
Remove the air inlet baffles and screw the self-tapping
screws back in place.
Replace the vermiculite trays (2+3) and the strip (1) in the
appliance.
NB: the maximum length of horizontal pipe must
not be exceeded.
Fig. 4 illustrates how to calculate the total lengths of pipe.

Connecting the Gas Supply

With the appliance a 40 cm flexible stainless steel gas hose
with G3/8" nipple joint has been supplied to
facilitate quick and easy installation. An approved
connecting tap with coupling should be used in the supply
hose (In Belgium this must be B.G.V. approved).
Furthermore:
• Expel all air from the supply pipes/hoses before coupling
to the appliance.
• Do not turn the coupling tap when connecting it to the
gas supply.
• Avoid any pressure on the control tap and pipes.
• Check that all connections are gastight.
Distance
damper
26 mm
32 mm
37 mm
42 mm
OPEN
OPEN
OPEN