INSTRUCTIONS FOR INSTALLATION
Any chimney previously used for an appliance burning a
fuel other than gas shall be swept thoroughly before
installing any gas appliance.
Appliances shall be connected only to the types and sizes
of flue system as specified.
For any other information about this flue system please
contact Drugasar or Drugasar approved agent.

Baffle

40
35
To ensure that the appliance
30
works satisfactorily,
it will need to be adjusted
according to the
customer-specific pipe system.
38c-1122
75
fig. 5
G25/G20
8 - 12 metres
vertical + roof duct
5 - 7 metres
vertical + roof duct
1 - 4 metres
vertical + roof duct
1m vertical +
1 - 3 mtr horizontal +
wall duct
1 m vertical +
wall duct
0,5 m vertical +
2 m horizontal +
wall duct
0,5 m vertical +
wall duct
Baffle
fig. 6
Air inlet
Damper
baffle
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
NO
NO
YES
NO
Adjusting the baffle.
The baffle plate is supplied separately and should be fitted
into the heater as indicated in fig. 6.
Use the adjustment jig provided (fig. 5) to adjust the baffle
to the right size. Once it has been adjusted, fix the damper
in place with the socket-head screw.
See the table for adjustment specifications.
In some cases the air inlet baffle should be removed
(tabel).
To do this: (fig. 7).
Take strip (1) and the vermiculite trays (2+3) out of the
appliance.
Remove the air inlet baffles and screw the self-tapping
screws back in place.
Replace the vermiculite trays (2+3) and the strip (1) in the
appliance.
NB: the maximum length of horizontal pipe
must not be exceeded.
Fig. 4 illustrates how to calculate the total lengths of pipe.

Connecting the Gas Supply

An approved connecting tap with coupling should be used
in the supply hose (In Belgium this must be B.G.V.
approved). Furthermore:
• Expel all air from the supply pipes/hoses before coupling
to the appliance.
• Do not turn the coupling tap when connecting it to the
gas supply.
• Avoid any pressure on the control tap and pipes.
• Check that all connections are gastight.
Distance
damper
30 mm
35 mm
40 mm
OPEN
75 mm
OPEN
OPEN
20