Electrical installation

Control terminals

Important notes

5.5
Control terminals
5.5.1
Important notes
(
Stop!
The control card will be damaged if
ƒ
ƒ
Limit the voltage before switching on the drive controller:
ƒ
ƒ
For trouble−free operation, the control cables must be shielded:
ƒ
– Connect the shield of digital input and output cables at both ends.
– Connect the shield of analog input and output cables at one end (at the drive
controller).
– For lengths of 200 mm and more, use only shielded cables for analog and digital
inputs and outputs. Under 200 mm, unshielded but twisted cables may be used.
90
the voltage between X5/39 and PE or X6/7 and PE is greater than 50 V,
the voltage between voltage source and X6/7 exceeds 10 V (common mode)
in case of supply via external voltage source.
Connect X5/39, X6/2, X6/4 and X6/7 directly to PE or
use voltage−limiting components.