Connecting the drive motors

The motor cables must be routed in such a way that they can-
not be torn off or damaged.
Shorten the motor cable of the drive motor furthest from the
control unit. Cut the motor cable of the closer drive motor to
the same length. The two motor cables of the drive motors
must be the same length to ensure that the manoeuvring as-
sistant can move the same distance. Excess cable must be
routed in wavy lines without loops.
Crimp the spade connectors provided onto the drive motor
cable. Release flap of control unit connection strip by press-
ing, and clamp cable in accordance with connecting diagram
(red = positive, black = negative). Please ensure that the
connections are made properly.
22
Drive
Drive
motor
motor
Battery
+
4
3
2
+
+
A
-
+
Drive
Drive
motor
motor
Battery
+
4
3
2
+
B
-
+
RH 1 Manoeuvring Assistant

Connecting the battery

Liquid electrolyte batteries must be installed in a separate box
with ventilation leading to the outside. The fuse in the positive
lead must be connected outside the box. A separate box is not
required for gel or AGM batteries. Pay attention to the battery
manufacturer's installation instructions.
1
The outgoing lines from the terminals must be routed with a
gap between them until after the fuse in the positive lead.
B
Figure 31
Route the battery connector cables (only use the original
cables supplied) to the control unit and attach them securely
using the clips and screws provided.
The battery connector cables must not be extended. They
must be routed separately from the motor cables, and
1
must not run over the control unit.
Route battery connector cables so that they do not chafe
+
(particularly at leadthroughs through metal panels). Use suit-
able protective leadthrough bushing to prevent damage to
A
cables. Connect battery connector cables to the existing bat-
tery terminals (red = positive, black = negative).
Incorrect polarity will destroy the electronics / control unit
The connection to the control unit (as per the connecting dia-
gram) must be made in the order: nut, battery connection ring
eyelet, nut (torque: 10 Nm ±1).
Connect fuse in the positive lead (150 A) near the positive
terminal.
-
+
-
+