Unauthorised modification and manufacture of spare parts
Unauthorised modification and manufacture of spare parts will impair the safety of the
product/personnel and is not permitted. This also applies to all installed plug and cable
connections on the product. Non-observance results in a loss of any claims to damages
and it will void the manufacturer's declarations regarding safety.
2.8
Improper use
The operational reliability of the supplied product is only guaranteed if used as intended
and in accordance with section 4 of the installation and operating instructions. The limit
values must on no account fall below or exceed those values specified in the catalogue/
data sheet.

3 Transport and temporary storage

On arrival, immediately check the product and its packaging for damage in transit. If dam-
age from transit is identified, the necessary steps must be taken involving the carrier
within the specified period.
CAUTION! Risk of personal injury and material damage!
Incorrect transport and temporary storage can cause damage to the product and per-
sonal injury.
• The pump and its packaging must be protected against moisture, frost and mechanical
damage during transport and interim storage.
• Dry pump thoroughly following use (e.g. function test) and store for a maximum of
6 months.
• Packaging that has been sodden loses its strength and can cause injury to persons if
the product falls out.
• When the pump needs to be transported, it may be carried only by the motor/pump
housing. Never by the control module or cable.

4 Intended use

The high-efficiency pumps of the Wilo-Stratos PARA/-Z series are for the circulation of
liquids (no oils or liquids containing oil, no media containing foodstuffs) in
• Hot-water heating systems
• Cooling and cold water circuits
• Closed industrial circulation systems
• Solar installations
• Geothermal systems
WARNING! Health hazard!
Because of the materials used in their construction, pumps of the Wilo-Stratos PARA
series must not be used in applications involving drinking water or foodstuffs.
Pumps of the Wilo-Stratos PARA-Z series are additionally suitable for use in
• domestic hot water circulation systems.