11. Remove functional part

11.1 Remove the sealing cap (siehe
11.2 Close the flow volume regulator.
11.3 Remove the safety ring.
11.4 Remove the pressure cap and spring.
11.5 Use a socket spanner to unscrew the functional part.
11.6 Reassemble in the reverse order.

12. Fault correction

Fault
Water does not flow at
all
Water flows conti-
nuously
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
6
Kapitel
Cause
– Water supply interrupted
– Flow volume regulator closed
– Functional part faulty
– Functional part/upper section faulty
– Flow volume regulator not fully
opened
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
10.1).
Remedy
➯ Restore
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it