16. Replace the non-return valve

Warning!
All non-return valves must be replaced at once.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
The non-return valve forms part of the guide socket (a).
16.1 Remove the fitting (see
16.2 Replace the guide socket (a).
16.3 When necessary, replace the O-rings of the guide socket (b).
16.4 Reassemble in reverse order.

17. Replace the aerator

17.1 Remove the aerator, using an open-ended wrench.
17.2 Replace the aerator.

18. Replace the functional element

18.1 Disassemble the pressure cap up to the temperature stop ring (see
Important!
When removing the functional element, ensure that the cartridge (a) remains in the
fitting.
18.2 Replace the functional element (b).
18.3 Set the temperature limits (see