11. Function

Water flow
11.1 Press the pressure cap.
• The water will flow.
• The water flow stops automatically once the preset flow time has expired.
The flow time is adjustable from 5-20 seconds.
Temperature selection

12. Adjusting the flow time

12.1 Undo the grub screw (a), using a hexagonal wrench.
12.2 Remove the pressure cap (c) and the spring (b).
12.3 Use a screwdriver to set the flow time.
+ longer flow time (max. 20 s)
– shorter flow time (min. 5 s)
12.4 Trigger the fitting to measure the flow time.
Important!
When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove.
12.5 Once the desired flow time has been set, put the pressure cap in place.
12.6 Reassemble in reverse order.

13. Adjust the temperature limits

Warning!
If the hot water supply temperature is above 45°C, the temperature limits should be set.
Failure to observe this instruction can result in injuries due to scalding.
The temperature limits are not an active scald protection.
13.1 Close the water supply.
13.2 Disconnect the fitting.
13.3 Turn the pressure cap (b) anti-clockwise up to the cold-water limit stop.
13.4 Undo the grub screw (a), using a hexagonal wrench.
13.5 Remove the pressure cap (b).
13.6 Remove the spring (e).
13.7 Loosen the housing nut (d), using a face spanner.
13.8 Remove the complete ball bearing (c).