Function; Adjusting The Flow Time - Franke AQRM274 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
10.1 Install the screw connections (a).
10.2 Install the screw rosettes (b).
10.3 Insert the filters (c).
10.4 Install the fitting (e) with the cap nuts (d).
10.5 Insert the flow rate regulator (g, included with shower head) and the seal (h, included
with shower head) into the fitting.
10.6 Attach the shower pipe (f) to the fitting.
10.7 Open the water volume regulators (i).
10.8 Check the water connections for leaks.

11. Function

Trigger the flow of water
11.1 Press the pressure cap.
• The water will flow.
• The water flow stops automatically once the preset flow time has expired.
The flow time is adjustable from 1-50 seconds.
Temperature selection

12. Adjusting the flow time

12.1 Using a screwdriver, carefully take off the stopper.
12.2 Remove the stopper.
12.3 Release the grub screw with an Allen key.
12.4 Remove the pressure cap.
12.5 Use a screwdriver to set the flow time.
a: Blade width 3 mm
+ longer flow time (max. 50 s)
– shorter flow time (min. 1 s)
12.6 Trigger the fitting to measure the flow time.
Important!
When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove.
12.7 Once the desired flow time has been set, put the pressure cap in place.
12.8 Reassemble in reverse order.
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqrm276b76129821172377612982116001

Table des Matières