Replacing The Functional Part; Fault Correction - Franke AQRM653 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

20. Replacing the Functional Part

20.1 Close the flow volume regulator (see
20.2 Trigger the valve.
20.3 Remove the push-cap handle (see
20.4 Remove the circlip.
20.5 Remove the pressure spring and the handle socket.
20.6 Use a socket spanner to remove the functional part.
Important!
While fitting the push-cap handle, make sure that the driving lug locks properly into
the corresponding groove (see
20.7 Reassemble in the reverse order.

21. Fault Correction

Fault
Water does not flow
Water flows conti-
nuously
Water flow too weak
Flow duration too
short or too long
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Arbeitsschritt
Chapter
Chapter
Cause
– Water flow regulator closed
– Functional part faulty
– Functional part faulty
– Flow volume regulator in shower
head calcified
– Shower head calcified
– Supply pressure too low
– Grit filter/Non-return valve dirty
– Water volume regulator is not fully
opened
– Incorrect setting
– Grit filter is clogged
– Shower head calcified
– Functional part faulty
– Temperature limiter/scald protector
is incorrectly set or not set at all
– Cold water is turned off
– Grit filters/Non-return valves in the
cold-water connection are faulty
– Grit filters/non-return valves in the
hot-water connection are faulty
– Hot water is turned off
- 10 -
15.1).
13.).
13.).
Remedy
➯ Restore it
➯ Replace it
➯ Replace it
➯ Clean, replace if
necessary
➯ Clean it
➯ Check it
➯ Clean it
➯ Open it
➯ Adjust it
➯ Clean it
➯ Clean it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Replace them
➯ Replace them
➯ Open it

Publicité

Table des Matières
loading

Table des Matières