11. Remove upper section

11.1 Interrupt the water supply.
11.2 Remove the sealing cap (see
11.3 Remove the locking washer.
11.4 Remove the pressure cap and spring.
11.5 Use a socket spanner (SW 27) to unscrew the upper section.
11.6 Reassemble in the reverse order.

12. Fault correction

Fault
Water does not flow at
all
Water flows
continuously
Duration too short or
too long
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
6
chapter
10.1).
Cause
– Stop valve or flow volume regulator-
closed.
– Upper section faulty
– Activation valve faulty
– Upper section faulty
– Activation valve faulty
– Flush volume adjustment incorrect
– Upper section faulty
– Stop valve or flow volume regulator-
not fully opened.
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
Remedy
➯ Open it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Adjust it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it