12. Remove functional part

12.1 Remove the sealing cap.
12.2 Remove the safety ring.
12.3 Remove the pressure cap and spring.
12.4 Use a socket spanner to unscrew the functional part.
12.5 Reassemble in the reverse order.

13. Fault correction

Fault
Water does not flow
at all
Water flows
continuously
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
6
Cause
– Water supply interrupted
– Flow volume regulator closed
– Functional part faulty
– Functional part faulty
– Volume flow rate controller is closed
– Flow volume regulator not fully
opened
– Supply pressure too low
– Volume flow rate controller not fully
opened
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
– Volume flow rate controller not fully
opened
Remedy
➯ Restore
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it
➯ Adjust it
➯ Close it