Step 7, Connect Electrical; Step 8, Install Duct Cover And Utensil Rods - GE Monogram ZV750 Instructions D'installation

Masquer les pouces Voir aussi pour Monogram ZV750:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING:
with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum,
be sure to use U.L. approved antioxidant compound
and aluminum-to-copper connectors.
• Remove the junction box cover and the selected
knockout.
Knockout
Junction
box cover
• Secure the house wiring to the junction box with
a strain relief.
• Connect the white lead to the branch circuit white lead.
• Connect the black lead to the branch circuit black lead.
• Connect the green/yellow lead to the branch
circuit green lead or bare ground lead.
• Secure all the connections with wire nuts on each
electrical connector.
• Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
• Secure the junction box cover with the 2 original
screws.
Installation Instructions
INSTALLATION – RECIRCULATING
If house wiring is not 2-wire
8
INSTALL DUCT COVERS AND
UTENSIL RODS
• Assemble the duct covers as shown.
Mounting screw holes
For this recirculating installation, the vent holes must
be positioned at the top. The vent holes must be fully
exposed to allow airflow into the room.
• Insert the duct cover assembly into the impressions
on the top of the hood.
• Extend the inner duct cover upwards to meet the
ceiling and support frame.
Install optional accessory ZX7510SPSS
(if needed to reach taller ceiling heights)
• Separate the supplied duct cover. Discard the lower
(outer) section.
• Slide the new ZX7510SPSS duct cover into the original
upper section. Be sure that the vent holes are
positioned toward the top.
• Insert the duct cover assembly into the impressions
on the top of the hood.
• Secure the duct cover at the top to the air deflector
with 2 screws provided.
• Install the side utensil rods as shown with screws
provided.