STEP 2 CONNECT ELECTRICAL

Verify that power is turned off at the source.
WARNING:
2-wire with a ground wire, an electrician will need
to convert existing wiring to meet these specs.
When house wiring is aluminum, be sure to
use U.L.-approved anti-oxidant compound
and aluminum-to-copper connectors.
1. Place insert sleeve on padded, yet stable, surface
below cutout (can use flattened carton to pad
surface).
2. Remove the junction box cover.
Wires
3. Pull house wires through wall of insert sleeve and
attach the strain relief. Thread the house wire
through the junction box.
Installation Instructions
If house wiring is not
Connect
4. Connect white leads to branch circuit white lead.
5. Connect black leads to branch circuit black lead.
6. Connect green/yellow leads to branch circuit green
lead.
7. Secure all connections with wire nuts on each
electrical connector.
Screws
8. Carefully push wires into junction box and replace
cover.
9. Secure junction box cover with original screws.
18
Cover

Publicité