7. Pressure lost
or iron in
conditioned
water.
8. Loss of resin
through drain
line.
9. Control cycle
continuously.
10. Drain flows
continuously.
11. Salt water in
soften water.
12. Interupted or
irregular brine.
13. Water flow out
from drain or
brine pipe after
regeneration.
14. Cycle water
treat capacity
decreases.
40
A. Iron in the water supply pipe.
B. Iron mass in the softener.
C. Fouled resin bed.
D. Too much iron in the raw water.
A. Air in water system.
B. Bottom strainer broken.
C. Improperly sized drain line control.
A. Controller is faulty.
B. Time of regeneration steps were set to
zero
C. Locating signal wiring breakdown
D. Foreign material stuck the driving gear.
A. Internal valve leak.
B. When electricity fails to supply, valve
stops backwash or fast rinse position.
C. Control valve is in Backwash status.
A. Foreign material in injector or injector
fails to work.
B. Brine valve cannot be shut-off.
C. Time of rapid rinse too short.
A. Water pressure too low or not stable.
B. Injector is plugged or faulty.
C. Air in resin tank.
D. Floccules in resin tank during backwash.
A. Foreign material in valve which makes
valve can't be closed completely.
B. Hard water mixed in valve body.
C. Water pressure is too high which result
in valve doesn't get the right position.
A. Unit fails to regenerate or regenerate not
properly.
B. Fouled resin bed.
C. Salt setting not proper.
D. Softener setting not proper.
E. Raw water quality deterioration.
F. Turbine of flow meter is stuck.
A. Clean the water supply pipe.
B. Clean valve and add resin cleaning
chemical, increase frequency of
regeneration.
C. Check backwash, brine draw and
brine tank refill. Increase frequency of
regeneration and backwash time.
D. Iron removal equipment is required to
install before softening.
A. Assure that well system has proper air
eliminator control.
B. Replace the bottom strainer.
C. Check for proper drain rate.
A. Replace the controller.
B. Check program setting and reset.
C. Check and connect locating signal
wiring.
D. Take out foreign material.
A. Check and repair valve body or replace
it.
B. Adjust valve to service position or
turn off bypass valve and restart when
electricity supply.
A. Clean and repair injector.
B. Repair brine valve and clean it.
C. Extend rapid rinse time.
A. Increase water pressure.
B. Clean or replace injector.
C. Check and find the reason.
D. Clean the floccules in resin tank.
A. Clean foreign material in valve body.
B. Change valve core or sealing ring.
C. Reduce water pressure or use pressure
release function.
A. Regenerate according to the correct
operation requirement.
B. Increase backwash flow rate and time,
clean or change resin.
C. Readjust brine drawing time.
D. According to the test of outlet water,
recount and reset.
E. Regenerate unit by manual temporary,
then reset regeneration cycle.
F. Disassemble flow meter and clean it or
replace it with a new turbine.