8. Starting water softener operation
HELP ON YOUR DEVICE START UP : This document does not replace the installation manual.
Thank you to refer it on installation and setup steps.
1 - Material
Water inlet
3 bar
pressure
reductor
Mandatory
2 - Water hardness measuring
Test reagent
not supplied
Keep the result value, it will be useful on step 8.
4 - Adding salt
NB : complete the filling after step 9
and 50 kg of salt for other models.
6 - Connect to power mains socket
Connect the device to the main power
Connect the device to the main power
Connect the device to the main power
(standardized plug).
9 - Launching a recharge
Unlock the screen by pressing
Launch the recharge by pressing
Run and check all the recharge cycles:
10 - Hardness of water setting
Wit a flat screwdriver, residual water hardness can be set. It must be in a range from 8°f to 12°f.
Unscrew a first time the screw on top of its place, then adjust to obtain the desired value.
NB: unscrew to rise and screw to reduce the hardness.
Measure again (step 2) to check your setting. Let the water flow for 1 to 2 minutes after each
adjustment.
Your Altech softener is properly installed. Check it during the next 48 hours.
11 - Y our Comap WT softener is properly installed. Check it during the next 48 hours.
36
Make sure there is all following elements on your installation:
Tap for
drinking
water
Supplied test strips
OR
Add the salt EN 973
necessary to recharge : 3 kg.
with maximum 15 kg of salt
for the 8 l model
7 - Time setting
230 V~ 50-60 Hz
To access the menu press
Use the
to select "set clock".
Press
Set the time, using the
Press
Press
8 - Water volume setting (previous page)
and
simultaneously.
1. Isolating valve before installation. Mandatory.
2. Standard isolator. Mandatory.
3. Sediment filter. Strongly advised
(filtering delivered with the softener).
4. Hoses
5. Electric transformer. Mandatory.
6. Brine evacuation pipe. Mandatory.
7. Overflow evacuation pipe. Mandatory.
8. Siphon with isolator. Mandatory : salt storage tank
overflow and head drain must be connected to the sewer
with an isolated siphon preventing sewer to reject waste
water In the system.
3 - Adding water
5 - Checking Bypass and outlet/inlet
Inlet
and
keys
to access the menu.
and
to confirm.
to quit the menu.
(previous pages 33 and 34)
Phase 1
Phase 2
Phase 3
Phase 4
Adoucisseur Priméo 18 L - 6997865 - ABRI820246 - 2022/10- Ind C
Put some water in the bottom of the
tank:
- 4 liters for an 8L softener,
- 15 liters for other models.
Outlet
Ensure that the moun-
ting clamps are correctly
installed and check outlet/
inlet.
Put the Bypass on.
NB : to unlock the screen
press
and
10 seconds.
keys.
Water to sewer
Water level in salt tank goes down
the water to sewer
Water level in slat tank rises
Water to sewer