5.3.4
Data on the process control system
DP read register (status information and readings)
Description without a text block
byte
0 - 1
2 - 3
4 - 5
6 - 9
10 - 13
14 - 17
18-21
22-25
26-29
30-33
34-37
38-41
42-45
Word = 16-bit data word
Long = data double word
Note:
When range 1 and range 2 are set, the scale is in range 3.
The bold print identifiers are not transmitted and they are only used to refer to the
list of the "Available Data".
Refer to the chapter on Available Data for the Controller Data for the reading ID list
DISOMAT Opus, Satus, Tersus, Data Communication
© Schenck Process
Identifier
Contents
0x300C
Function block PLS-Dout 1-16
0x3000
The scale status on the scale displayed
0x3002
Request (ID1 mirrored)
0x4000
Gross weight on the scale displayed
unrounded in kg
0x4010
Gross weight on the scale displayed
rounded off in the display format
See list for ID
Value 1
See list for ID
Value 2
See list for ID
Value 3
See list for ID
Value 4
See list for ID
Value 5
See list for ID
Value 6
See list for ID
Value 7
See list for ID
Value 8
BV-H2359GB/0902
5.3 Profibus DP protocol
83