Coupling for SPS and PLC
General control telegram: (commands)
Slave
address
(1 byte)
Wordwise presetting of commands:
Slave
address
0x01-0xfe
For example, wordwise presetting (commands):
Slave
address
0x01
0x01
0x01
0x01
0x01
Note:
You can only specify commands with FC 6 or 16 because this is a number, not
bit-coded data. This means that only one command can be executed per
transmission.
For example, for bitwise presetting via function block (PLS-DIn 1-16):
Slave address
0x01
0x01
0x01
Data addresses
0x0010
0x0020
0x0020
DISOMAT Opus, Satus, Tersus, Data Communication
© Schenck Process
FC
Data address
(1 byte)
(2 bytes)
Data address
FC
0x0010
0x06
FC
Data address
0x06
0x0010
0x06
0x0010
0x06
0x0010
0x06
0x0010
0x06
0x0010
FC
Data address
0x05
0x0020
0x05
0x0020
0x06
0x0020
Low Byte
Low Byte function blocks
High Byte function blocks
BV-H2359GB/0902
Data
CRC
(2 bytes)
(2 bytes)
Data
CRC
(1 Wort)
Data
CRC
0x0001
0x0002
0x0003
0x0080
0x0000
Data
CRC
0xFF00
0x0000
0x0010
Meaning
Command number (refer to the chapter on
Available Data Specifications)
PLS -DIn-1
bit address
PLS -DIn-2
PLS -DIn-3
PLS -DIn-4
PLS -DIn-5
PLS -DIn-5
PLS -DIn-6
PLS -DIn-7
PLS -DIn-8
PLS -DIn-9
bit address
PLS -DIn-10
PLS -DIn-11
PLS -DIn-12
PLS -DIn-13
PLS -DIn-14
PLS -DIn-15
PLS -DIn-16
5.1 Modbus-RTU
Meaning
Taring
Clear tare
Zero setting
Acknowledge
error
Reset
Meaning
Set PLS-DIn 1
Reset PLS-DIn 1
Set PLS-DIn 5
0x0020
0x0021
0x0022
0x0023
0x0024
0x0024
0x0025
0x0026
0x0027
0x0028
0x0029
0x002A
0x002B
0x002C
0x002D
0x002E
0x002F
55