GB
Instructions For Use Machine Light MCEYL 3 S „SPOT LED 003"
Description
SPOT LED 003
20
According to standard DIN EN 1837 , an illuminance of 500 lx is required in the work area of machines. This is
often impossible to achieve using a light that is not in the immediate proximity of the tool. However, only in rare
cases is it possible to attach a light directly to the tool slide, since the restricted room available in the interior of
the machine room does not allow this.
In the ideal case, a well illuminated machining area is achieved by combining 2 or more lights:
a) Light for basic illumination of the machining area (using, for example, a Waldmann protective tube light)
b) Additionally mounted light for the immediate machining area (e.g. Waldmann machine light MCXFL 3, MCTFL
3 or MCBFL 3) or use of built-in light MCEYL 3.
The built-in light MCEYL 3 meets the requirements from the standardif the machining area is clearly defined
and no flexibility is required.
The use of light emitting diodes (LED) instead of halogen lights allows a significantly higher useful life to be
achieved. This results in fewer machine downtimes as a result of maintenance work.
A housing made of anodised aluminium and a protective borosilicate glass pane are resistant to hot and sharp-
edged chips. The housing is water-proof and resistant to coolants and lubricants.
The selection between several variants of different radiation characteristics makes for universal use.