sYMPTOM
Jammed nail
CAUsE
Wrong size or angle nails.
Material and fastener length.
Debris in nosepiece.
Worn magazine.
Damaged or worn return springs.
Damaged or worn profile.
FiX
Use only the recommended nails. Refer to Nail Specifications.
If the unit continues to stall (forcing the need to rotate the stall
release lever) choose the appropriate material and fastener
length that is not too rigorous an application.
Clean nose area and watch closely for small pieces of broken
nails stuck in the track.
Replace magazine. See authorized service center.
Replace springs. Refer to Return Spring Replacement or see
authorized service center.
Replace profile. Refer to Replacing the Profile or see
authorized service center.