7 Repairing minor faults

The unit...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
*France: 0.806.800.107 (call charge).
7.1
Cleaning the exhaust silencer
1.
Remove the nuts (A4) and the enclosure (A3).
2.
Remove the screws (F1) and the cover from the exhaust silencer (F2).
3.
Remove the screw (F3) and the exhaust silencer (F4).
4.
Remove the exhaust silencer grille (F5) then the spark arrester (F6).
5.
Using a metal brush, carefully remove the deposits on the exhaust silencer grille and spark arrester.
6.
Check the condition of the spark arrester and the exhaust silencer grille. Replace them if they are damaged.
7.
Refit the spark arrester.
8.
Refit the exhaust silencer grille and the exhaust silencer by tightening the screw correctly.
9.
Refit the exhaust silencer cover and its screws.
10. Refit the enclosure by retightening the nuts correctly.

8 Technical specifications

8.1

Operating conditions

The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
Check that:
The equipment to be used has not
been connected prior to starting.
YES
The switch is at
or
YES
The battery is correctly connected and
charged.
YES
The fuel tap is in the ON position.
YES
The spark plug is in good condition and
correctly connected.
YES
The oil level is correct, the oil cut-out
warning light is off.
YES
The fuel level is correct.
YES
Maintenance has been correctly
performed on the unit components.
YES
Have the unit checked by one of our
agents*.
The circuit breaker for the 12V socket
is triggered.
YES
The capacity of the unit is not
exceeded; the overload warning light is
off.
YES
The connected equipment and their
power cords are not faulty.
YES
Have the unit checked by one of our
agents*.
23/182
Disconnect the equipment then try to start
NO
.
Set the switch to
NO
Install the battery; replace it with a new
NO
Turn the fuel tap to the ON position.
NO
NO
NO
NO
Perform maintenance on the unit as per
NO
Press the circuit breaker for the 12V
NO
NO
Try with another item of equipment and
NO
Solutions to be applied:
the unit again.
or
.
battery if necessary.
Check the spark plug.
Top up with oil.
Fill up with fuel.
the recommendations.
socket to trigger it.
Reduce the load.
another power cord.