Zivan NG5 Manuel D'installation Et D'utilisation page 14

Can bus interface
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
English
Firmware Release indication (if display is present – CB firmware only)
When the charger is turned on, the display will show "Fir" follone by a number. This number indicates the firmware release: for example,
"1.03" means CB CURVE, revision 1.03.
Alarms
When an alarm situation stopping the charge occurs, the display shows one of the information below according failure detected:
The table below describe the alarm list.
Display code
1
2
3
5
6
7
8
HIGH TEMPERATURE
9
MISMATCH VOLTAGE
10
11
12
13
14
15
16
17
18
21
29
CLOCK BATTERY OFF
30
Notes:
A05:
The charge restarts once the battery temperature reaches a value lower than 50°C.
A11:
Notice on the battery status. By pressing the MODE button, a desulphation phase start followed then by the standard charge.
A12:
Notice on the battery status. The standard charge is starting anyway
A15:
With the thermal sensor out of order the battery charger behaves as if it was not equipped with the external probe
Each temporary alarm, restarts the charge after alarm conditions disappear.
Each alarm, except the non-blocking ones, give also an audible alarm
14
NG5-7-9 CAN Bus Interface
<A> <alarm code identified with a 2 digits code>
Alarm Type
LOGIC FAILURE #1
CAN BUS KO
WATCHDOG
HIGH BATTERY
TEMPERATURE
MISSING PHASE
OVERCURRENT
TIMEOUT
OVER DISCHARGE
DEEP DISCHARGE
CONNECTION FAULT
PUMP MISTAKE
TH. SENSOR KO
LOGIC FAILURE #2
FLASH CHECKSUM
EEPROM KO
LOGIC FAILURE #3
NODE RESET
Charge stop
Trouble on current circuit (turn off/on the charger. If the
Yes
problem persists please contact customer service).
Trouble on CAN communication (verify CANBUS
No
communication).
Logic board trouble (turn off/on the charger. If the problem
Yes
persists please contact customer service).
Battery temperature over than 55°C (the charger restarts when
Temporary
battery temperature goes under 50°C).
One of the three input phase cannot be detected by the
Temporary
charger (check for all three phases to be connected to the
charger, or contact customer service) .
Anomalous input current absorption (charger restarts after 3
Temporary
seconds. If the problem persists please contact customer
service).
Internal high temperature (turn off/on the charger. If the
Yes
problem persists please contact customer service).
Trouble on voltage circuit (turn off/on the charger. If the
Yes
problem persists please contact customer service).
End of Phase 1 due to timeout (check if charger is suitable for
Temporary
the specified battery type – disconnect the battery).
No
Over discharged battery
No
Deeply discharged battery.
Connection fault in the output cables. Disconnect the battery
Temporary
and wait for the display to show three dots before connecting a
new battery.
No
Air pump mis-working
No
Thermal sensor failure.
Voltage sag (charger restarts after 3 seconds. If the problem
Temporary
persists please contact customer service).
Error in flash memory (turn off/on the charger. If the problem
Yes
persists please contact customer service)
Problem in EEPROM communication (turn off/on the charger.
Yes
If the problem persists please contact customer service).
The output voltage has exceed a safety threshold (turn off/on
Yes
the charger. If the problem persists please contact customer
service).
The Clock battery is discharged or removed (if the battery
No
needs to be replaced contact customer service)
The CAN Node has been set to 126, which is a forbidden
Yes
value (the charger forces you to enter the "Changing curve
selection" described in the previous page)
Description
D01755-07

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ng7Ng9

Table des Matières