The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 60Hz, 250W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
GROUNDED
POWER CORD
VW-1, 105°C/221°F,
FUEL INPUT RATING:
18-3 STANDARD CSA
2.0 KG/H (4.4 LB/H)
FIRE POT
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
38
ELECTRICAL WIRE DIAGRAM
LOCATE AND REMOVE
THE EIGHT SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
K
K
W
W
G
GROUND
W
P
W
W
W
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
200W, 120V
K
TEMPERATURE PROBE
MOLEX CONNECTOR
FAST-BLOW FUSE
P
Y
P
Y
R
W
W
R R
AUGER MOTOR
& FEED SYSTEM
120V, 50/60Hz, 2 RPM
MOTOR
GRILL
PROBE
CONTROL BOARD
Y
Y
Y
DRAFT FAN
120V, 50/60Hz, 1 PHASE