Télécharger Imprimer la page

DeWalt D55180 Guide D'utilisation page 30

Masquer les pouces Voir aussi pour D55180:

Publicité

Les langues disponibles

Les langues disponibles

CODE
POSSIBLE CAUSE
33
Regulator open
34
Possible defective motor or starting capacitor
35
Paint spray on internal motor parts
36
Fuse blown, circuit breaker tripped
POSSIBLE SOLUTION
Rotate the regulator knob counterclockwise to its built-in stop
and push knob in to lock in place.
Contact a D
WALT factory service center or a D
E
authorized service center.
Contact a D
WALT factory service center or a D
E
authorized service center. Do not operate the compressor in
the paint spray area. See flammable vapor warning.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. You should use a time delay
fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
30
WALT
E
WALT
E

Publicité

loading

Ce manuel est également adapté pour:

D55170D55390D55395D55570D55575D55580 ... Afficher tout