Télécharger Imprimer la page

DeWalt D55180 Guide D'utilisation page 19

Masquer les pouces Voir aussi pour D55180:

Publicité

Les langues disponibles

Les langues disponibles

WARNING: Risk of property damage. Over tightening the Pilot Valve
knob can cause damage to the pilot valve.
7. Allow compressor to reach cut-out pressure. If compressor does
not stop, contact a D
WALT service center or call 1-800-4-D
E
for assistance.
IMPORTANT: Always turn pilot valve knob counter-clockwise until it
stops before moving the On/Off switch (C) to the OFF position
CONSTANT RUN MODE
1. Ensure the On/Off switch (C) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection under Installation.
3. Open the drain valve (counter-clockwise).
4. Move the On/Off switch to the ON position. The compressor will
start.
5. Turn knob on top of pilot valve (H) fully counter-clockwise until fully
open.
6. Close drain valve (clockwise).
WARNING: Risk of property damage. Over loosening the pilot valve
knob can cause damage to the pilot valve.
7. The compressor is now in constant run mode. If compressor shuts
off, contact a D
WALT service center or call 1-800-4-D
E
assistance.
NOTE: For proper operation the pilot valve blow-off pressure must be
below the pressure switch cut out pressure.
Shut-down
1 Move On/Off switch (C) to the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6. IMPORTANT: (D55390,
D55395, D55570, D55575, D55580, D55585) Always turn pilot
valve knob clockwise until it stops before moving the On/Off switch
(C) to the OFF position when unit is in the constant run mode.
2. Turn regulator knob (F) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
WALT
4. Drain the air tank, see Draining Air Tank under Maintenance.
E
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING: Risk of bursting. Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk of
air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure On/Off switch is in the OFF position.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE: All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
WALT for
accordance with local, state, and federal laws and regulations.
E
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should be
performed by a D
E
rized service center.
19
WALT factory service center or a D
WALT autho-
E

Publicité

loading

Ce manuel est également adapté pour:

D55170D55390D55395D55570D55575D55580 ... Afficher tout