Power up
Use
Partial malfunction
Total malfunction
CYCLIC FLASHING
POWER SUPPLY SECTION
7. "MAINS INPUT" POWER SUPPLY CONNECTOR
Compatible with powerCON TRUE1® connectors. Full-
range power supply.
8. "MAINS LINK" POWER SUPPLY LINK
Compatible with powerCON TRUE1® connectors to link
the power supply to other modules. To find out how
many modules can be connected in a linked system,
refer to the "CONNECTIONS" section in this manual.
9. MAINS FUSE
Mains fuse holder.
CAUTION!
• Only use the power cable provided or other dBTechnologies power cables.
• The USB SERVICE DATA connection is to be used exclusively for updating the product's
firmware; do not connect any other USB device to the unit to avoid the risk of damage and
malfunction.
• Do not use the monitor for a prolonged period with the limiter LED steadily lit or flashing as
this indicates operation under stress with excessive distortion.
VIO X315
26
Limiter
OFF
COMPRESSION
SIGNAL OUTPUT
LIMITER STATUS
ACTIVE
Signal
Status
STEADILY LIT FOR A
OFF
FEW SECONDS
STATUS
ACTIVE
CYCLIC FLASHING
OFF
STEADILY LIT
7
On
OFF
OFF
STEADILY LIT
STEADILY LIT
OFF
8
9
Cod. 420120425 REV. 1.0