Repair and customer service.
Before mounting or replacing application tools or accessories, remove the
WARNING
battery. This preventive safety measure rules out the danger of injuries
through accidental starting of the power tool.
Exchangeable parts
If required, you can change the following
parts yourself:
Application tools, clamping flanges, safety
cover, battery
When working gypsum-containing materi-
als, dust can settle within the power tool and
switch element, which can harden in con-
nection with humidity. This can impair the
switching mechanism. Blow out the interior
of the power tool via the ventilation slots
and the switch element frequently with dry
and oil-free compressed air.
Products that have come into contact with
asbestos may not be sent in for repair. Dis-
pose of products contaminated with asbes-
tos according to the applicable country-
specific regulations for such disposal.
For FEIN power tools and accessories in
need of repair, please contact your FEIN
after-sales service. The address can be found
on the Internet under www.fein.com.
Renew stickers and warning indications on
the power tool when aged and worn.
The current spare parts list for this power
tool can be found in the Internet at
www.fein.com.
Use only original spare parts.
Service.
Have maintenance carried
WARNING
out only through qualified
personnel. Incorrectly mounted leads and
components can cause serious injuries.
Have the required service carried out only
through a FEIN customer service agent.
Cleaning.
Remove the battery prior to
WARNING
any maintenance and clean-
ing. This preventive safety measure rules
out the danger of injuries through accidental
starting of the power tool.
When using in environments
WARNING
with conductive dust in the
air, such as when working metals, this dust
can settle in the interior of the power tool.
Therefore, regularly blow out the interior of
the power tool from outside via the ventila-
tion openings with dry, oil-free compressed
air; always wear eye protection when doing
this.
Do not attempt to clean
CAUTION
clogged or dirty ventilation
openings of the power tool with pointed
metal objects; use nonmetal tools or objects
if necessary.
Do not use cleaning agents
CAUTION
and solvents that can cause
damage to plastic parts. These include: Gas-
oline, carbon-tetrachloride, chloric solvents,
ammonia and domestic cleaning agents that
contain ammonia.
Occasionally clean the ventilation slots and
the battery terminals with a soft, clean and
dry brush.
– Do not use chemical substances for clean-
ing the battery.

Publicité