Emission values for sound and vibration (Two-figure – specifications as per ISO 4871)
Sound emission
A-weighted emission pressure power level measured at the
L
workplace
(re 20 μPa), in decibels
pA
Measuring uncertainty
Measured A-weighted sound power level
decibels
Measuring uncertainty
C-weighted peak sound pressure level measured at the
L
workplace
pCpeak
Measuring uncertainty
Vibrations
Mean vibrational value for angle grinding
2
– m/s
2
– ft/s
Mean vibrational value for sanding with sanding sheet
2
– m/s
2
– ft/s
Measuring uncertainty
2
– m/s
2
– ft/s
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
K
, in decibels
pA
K
, in decibels
wA
, in decibels
K
, in decibels
pCpeak
K
, in
L
(re 1 pW), in
wA
CCG18-125-10PD-SEC AS (**)
80.2
3
91.2
3
94.2
3
8.8
28.9
2.1
6.9
1.5
4.9

Publicité