Fault And Breakdown Code Display; Code Description; Accessing Memorised Data - SOMFY CONTROL BOX 3S io Manuel D'installation

Masquer les pouces Voir aussi pour CONTROL BOX 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Control Box 3S io

fault and breakdown code display

Code
description
E1
Cell safety autotest fault
E2
Programmable safety autotest
fault
E4
Obstacle detection when
opening
E5
Obstacle detection when
closing
E6
Cell safety fault
E8
Programmable safety fault
E9
Thermal protection
E10
Motor short circuit protection
24V power supply short
E11
protection
Hardware fault
E12
E13
Accessories power supply fault The accessories power supply cuts out following an
E14
Intrusion detection
E15
Fault when the control box
supplied by the backup battery
is first switched on
For all other error codes or faults, please contact Somfy.

Accessing memorised data

To access memorised data, select parameter "ud" then press "OK".
data
description
u0 to u1
Complete opening cycle
counter
u2 to u3
u6 to u7
Cycle counter with obstacle
detection
u8 to u9
u12 to u13
Pedestrian opening cycle counter
u14 to u15
Reset movement counter
u20
Number of monodirectional remote controls memorised for complete opening control
u21
Number of monodirectional remote controls memorised for pedestrian opening control
u22
Number of monodirectional remote controls memorised for remote lighting control
u23
Number of monodirectional remote controls memorised for auxiliary output control
u24
0 = no system key present, 1 = system key present
d0 to d9
Log of the last 10 faults (d0 most recent - d9 oldest)
dd
To clear the fault log: press and hold "OK" for 7 s.
21
Comments
The cell autotest is not satisfactory.
The programmable safety input autotest is not
satisfactory.
Detection in progress on safety input for longer than
3 minutes.
Thermal protection is correct
Short circuit protection for input/outputs: product
and additional devices connected to terminals
21 to 26 (orange light, photoelectric cells (except
BUS), code keypad) not operating
The hardware auto tests are not satisfactory
overload (excessive consumption)
Current reinjection function
global [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
since last auto-programming [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
global [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
since last auto-programming [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
Solution?
Check that "P07" is correctly configured.
Check the wiring of the cells.
Check that "P09" is correctly configured.
Check the programmable safety input wiring.
Check that no obstacles are causing the cells or safety edge to detect.
Check that "P07 or P09" is correctly configured in relation to the device
connected to the safety input.
Check the safety device wiring.
Check that the photoelectric cells are correctly aligned.
Check the motor wiring.
Check the wiring, then disconnect the power supply for 10 seconds.
N.B.: maximum accessories consumption = 1.2 A
Repeat an order. If the fault persists, contact Somfy.
N.B.: maximum accessories consumption = 1.2 A
Check the consumption of the connected accessories.
Normal operation (attempted intrusion, current reinjection activated, etc.)
Disconnect the backup battery and connect the control box to the mains to
switch it on for the first time.
Copyright © 2015 Somfy SAS. All rights reserved

Publicité

Table des Matières
loading

Table des Matières