11.2. Programming code display

Code
Description
H0
Awaiting setting
Hc1
Awaiting setting + 9.6
V power supply
Hu1
Awaiting setting + 24 V
power supply
H1
Awaiting start of
auto-programming
H2
Auto-programming
mode - opening
H4
Auto-programming
mode - closing
F0
Awaiting remote con-
trol memorisation for
operation in complete
opening mode
F1
Awaiting remote con-
trol memorisation for
operation in pedestrian
opening mode
F2
Awaiting remote con-
trol memorisation for
remote lighting control
F3
Awaiting remote
control memorisation
for auxiliary output
control
11
Comments
Pressing and holding the "SET" button
for 2 seconds starts auto-program-
ming mode.
Displayed during operation with 9.6 V
backup battery
Displayed during operation with 24 V
backup battery
Pressing the "OK" button starts the
auto-programming cycle.
Pressing the "+" or "-" button allows
the motor to be controlled in forced
operation mode.
Pressing a button on the remote con-
trol allocates this button to the motor
complete opening control.
Pressing "PROG" once more switches
to "awaiting remote control memorisa-
tion for operation in pedestrian opening
mode: F1".
Pressing a button on the remote con-
trol allocates this button to the motor
pedestrian opening control.
Pressing "PROG" once more switches
to "awaiting remote lighting control
memorisation: F2".
Pressing a button on the remote con-
trol allocates this button to the remote
lighting control.
Pressing "PROG" once more switches
to "awaiting auxiliary output control
memorisation: F3".
Pressing a button on the remote
control allocates this button to the
auxiliary output control.
Pressing "PROG" once more switches
to "awaiting remote control memorisa-
tion for operation in complete opening
mode: F0".

11.3. Error and breakdown code display

Code
Description
E1
Cell safety
The cell autotest is
autotest fault
not satisfactory.
E2
Programmable
The programmable
safety autotest
safety input autotest
fault
is not satisfactory.
E4
Obstacle
detection when
opening
E5
Obstacle
detection when
closing
E6
Cell safety fault Detection in progress
on safety input
E8
Programmable
for longer than 3
safety fault
minutes.
E9
Thermal pro-
Thermal protection is
tection
correct
E10
Motor short cir-
cuit protection
E11
24V power
Short circuit protec-
supply short
tion for input/outputs:
protection
product and addition-
al devices connected
to terminals 21 to 26
(orange light, photo-
electric cells (except
BUS), code keypad)
not operating
E12
Hardware fault The hardware
autotests are not
satisfactory
E13
Accessories
The accessories
power supply
power supply cuts
fault
out following an
overload (excessive
consumption)
E14
Intrusion
Current reinjection
detection
function
E15
Fault when
the control
box supplied
by the backup
battery is first
switched on
For all other fault and breakdown codes, please contact Somfy.
CONTROL BOX 3S io
Comments
Solution?
Check that "P07" is
correctly configured.
Check the wiring of the
cells.
Check that "P09" is
correctly configured.
Check the programma-
ble safety input wiring.
Check that no obsta-
cles are causing the
cells or safety edge to
detect.
Check that "P07 or
P09" is correctly con-
figured in relation to
the device connected
to the safety input.
Check the safety
device wiring.
Check that the
photoelectric cells are
correctly aligned.
Check the motor
wiring.
Check the wiring, then
disconnect the power
supply for 10 seconds.
N.B.: maximum acces-
sories consumption =
1.2 A
Request a gate
movement. If the fault
is still present, contact
Somfy.
N.B.: maximum acces-
sories consumption =
1.2 A
Check the consump-
tion of the connected
accessories.
If P07 = 4, check that
the bridge between
terminals 23 and 24 is
removed.
Normal operation
(attempted intrusion,
current reinjection)
Disconnect the backup
battery and connect