11.4. Accessing memorised data - Fig. 30

To access memorised data, select parameter "Ud" then press "OK".
Code
U0 to U1
Complete opening
cycle counter
U2 to U3
U6 to U7
Cycle counter with
obstacle detection
U8 to U9
U12 to U13
Pedestrian opening cycle counter
U14 to U15
Reset movement counter
U20
Number of remote controls memorised for complete
opening control
U21
Number of remote controls memorised for pedestrian
opening control
U22
Number of remote controls memorised for remote
lighting control
U23
Number of remote controls memorised for auxiliary
output control
U24
0 = no system key present, 1 = system key present
d0 to d9
Log of the last 10 faults (d0 most recent - d9 oldest)
dd
To clear the fault log: press and hold "OK" for 7 s.

12. TECHNICAL DATA

GENERAL SPECIFICATIONS
Power supply
Max. power consumption
Programming interface
Climatic operating conditions
Radio frequency
Unidirectional con-
trols (Keygo io, Situo
Number of
io, etc.)
memorisable
channels
Bidirectional controls
(Keytis io, Telis io,
Composio io, etc.)
CONNECTIONS
Type
Safety input
Compatibility
Wired control input
Remote lighting output
Orange light output
24 V controlled power supply output
Safety input test output
Accessories power supply output
Offset aerial input
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
Description
global [Hundred thousands - ten
thousands - thousands] [hundreds -
tens - units]
since last auto-programming [Hun-
dred thousands - ten thousands -
thousands] [hundreds - tens - units]
global [Hundred thousands - ten
thousands - thousands] [hundreds -
tens - units]
since last auto-programming [Hun-
dred thousands - ten thousands -
thousands] [hundreds - tens - units]
220-230 V - 50/60Hz
800 W (with 500 W remote
lighting)
7 buttons - 3-character LCD
screen
- 20°C/+ 60°C - IP 44
868 - 870MHz
< 25 mW
Complete/pedestrian opening:
30
Lighting: 4
Auxiliary output: 4
Unlimited
Dry contact: NF
TX/RX photoelectric cells - Bus
cells - Reflex photocell - Dry
contact output safety edge
Dry contact: NO
230 V - 500 W (Halogen or
incandescent only)
24 V - 15 W with integrated
flashing management
Yes: for possible autotest on TX/
RX photoelectric cells
Yes: for possible autotest on
reflex photocell or safety edge
24 V - 1.2 A max
Yes
Backup battery
Life
input
Charge time
OPERATION
Forced operating mode
Independent lighting control
Timed lighting (a er movement)
Automatic closing mode
Orange light warning
When closing
Security entry
operation
Before opening
(ADMAP)
Partial opening control
Gradual starting
Opening speed
Closing speed
Coupling speed when closing
Lock release - electric lock release
Holding gate in open/closed position
Gate leaf shi
Diagnostics
EN
Yes
24 hours; 3 cycles depending on
the gate
48 hours
Pressing the motor control
button
Yes
Programmable: 0 to 600 s
Yes: programmable reclosing
time delay from 0 to 255 min
Programmable: without or with
warning (fixed at 2 s)
Programmable: stop - partial
reopening - complete reopening
Programmable: no effect or
movement refused
Yes: complete opening of mo-
torised gate leaf by M1
Yes
Programmable: 10 possible
values
Programmable: 10 possible
values
Programmable: 5 possible
values
Programmable: active - inactive
By current reinjection in case of
detection when opening/closing
(only on Control Box 3S Axovia
models)
Programmable
Saving and consulting data:
cycle counter, cycle counter with
obstacle detection, number of
memorised radio channels, log
of the last 10 stored faults
12