CONTROL BOX 3S io
8.4. Memorising 3-button remote controls (Telis io,
Telis Composio io, etc.)
8.4.1. Button functions on a 3-button remote control
F0
Complete opening
F1
Complete opening
F2
Lighting ON
F3
Aux. output ON
8.4.2. Memorising via the programming interface - Fig.
32
To memorise a 3-button io bidirectional remote control (Telis io, Impre-
sario Chronis io, etc.), ensure that the remote control has memorised the
system key (see page 16).
1) Press and hold the "PROG" button (2 s) on the programming interface.
The screen displays "F0".
Pressing "PROG" again allows the next function to be memorised.
2) Press "PROG" at the rear of the 3-button remote control to memorise
the function.
The screen displays "Add".
8.4.3. Memorising by copying a previously memorised
3-button mono-directional io remote control -
Fig. 33
9. CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS
9.1. Clearing individual buttons on the Keytis io or
Keygo io remote controls - Fig. 34
This can be done:
• by memorising via the programming interface.
Memorising a button which has already been memorised will clear
this button's function.
• by clearing directly on the remote control (only on Keytis io remote
controls).
Press the "PROG" button and the BUTTON to be cleared on the re-
mote control together.

9.2. Clearing memorised remote controls - Fig. 35

Causes all memorised remote controls and the memorised system key to
be cleared.
On Keytis io remote controls, repeat the direct clearing procedure de-
scribed above for all of the memorised remote control buttons.

9.3. Keytis io remote control general reset - Fig. 36

Press the "PROG" and "KEY" buttons together. This causes:
• the programming to be completely cleared (all buttons),
• all the parameter settings on the remote control to be cleared (refer
to the instructions for the Keytis io remote control),
• the system key memorised by the remote control to be modified.

9.4. Reinitialising all settings - Fig. 37

Press the "SET" button until the light goes out (7 s).
Clears the auto-programming and resets the default values for all param-
eters.
10. LOCKING THE PROGRAMMING
BUTTONS FIG. 38
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
my
Stop
Complete closing
If gate is closed,
Complete closing
pedestrian opening
Otherwise stop
Lighting OFF
Aux. output OFF
Warning
The keypad must be locked to ensure the safety of the users.
Failure to follow this instruction may result in serious injury, e.g.
due to crushing by the gate.
Locks the programming (end limits, auto-programming, parameter set-
tings).
Press the "SET" buttons, "+", "-":
• - the "SET" button must be pressed first.
• - the "+" and "-" buttons must be pressed simultaneously within 2
seconds.
To access the programming again, repeat this procedure.
When the programming buttons are locked, a dot appears a er the
1st digit.

11. DIAGNOSTICS

11.1. Operating code display

Code
Description
C1
Awaiting command
C2
Open the gate
C3
Awaiting gate closure Automatic closing time delay P02, P04
C4
Close the gate
C6
Detection in progress
for cell safety
C8
Detection in progress
for programmable
safety
C9
Detection in progress
for emergency stop
safety
C12
Reinjecting current
C13
Safety device autotest
in progress
C14
Permanent complete
opening wire control
input
C15
Permanent pedestrian
opening wire control
input
C16
BUS cell programming
refused
Cc1
9.6 V power supply
Cu1
24 V power supply
Comments
or P05 in progress.
Displayed during a movement request
or during movement when the safety
input is active.
The display is maintained as long as
the safety input is active.
This display is only available on Control
Box 3S Axovia models.
Displayed while the autotest is running
on the safety devices.
Indicates that the complete opening
wire control input is permanently
activated (contact closed). Commands
coming from the radio remote controls
are then disabled.
Indicates that the pedestrian opening
wire control input is permanently
activated (contact closed). Commands
coming from the remote controls are
then disabled.
Check that the BUS cells (wiring, align-
ment, etc.) are operating correctly
Displayed during operation with 9.6 V
backup battery
Displayed during operation with 24 V
backup battery
EN
10