Description Of The Various Additional Devices; Advanced Parameter Setting; Navigating The Parameter List; Displaying The Value Of The Parameters - SOMFY Control Box 3S io Manuel D'installation

Masquer les pouces Voir aussi pour Control Box 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Terminals
Connection
27 Shared
Safety input 2 -
programmable
28 Contact
29 Contact
Safety test output
30 Contact
COMPLETE/OPEN-
ING control input
31 Shared
32 Contact
PEDESTRIAN/
CLOSING control
input
33 Conductor
Aerial
34 Braid

6.2. Description of the various additional devices

Warning
The peripheral cables must be secured using the cable clamps
supplied.
6.2.1. Photoelectric cells - Fig. 10
Warning
It is compulsory to install photoelectric cells WITH AUTOTEST P07
= 3 if:
- remote control of the mechanism (gate not visible) is used,
- automatic closing is activated ("P01" = 1, 3 or 4).
Three types of connection are possible:
A: Without autotest: programme parameter "P07" = 1.
B: With autotest: programme parameter "P07" = 3.
• Allows an automatic test to be carried out to check the operation of
the photoelectric cells each time the gate moves.
• If the operating test result is negative, the gate cannot be moved
until the operating mode changes to deadman operation (a er 3
minutes).
C: BUS: remove the bridge between terminals 23 and 24 then programme
parameter "P07" = 4.
Attention
Auto-programming must be repeated a er the cell BUS has been
connected.
6.2.2. Reflex photoelectric cell - Fig. 11
Warning
It is compulsory to install photoelectric cells WITH AUTOTEST P07
= 2 if:
- remote control of the mechanism (gate not visible) is used,
- automatic closing is activated ("P01" = 1, 3 or 4).
Without autotest: programme parameter "P07" = 1.
With autotest: programme parameter "P07" = 2.
• Allows an automatic test to be carried out to check the operation of
the photoelectric cell each time the gate moves.
• If the operating test result is negative, the gate cannot be moved
until the operating mode changes to deadman operation (a er 3
minutes).
6.2.3. Orange light - Fig. 12
Programme parameter "P12" according to the required operating mode:
• No warning prior to gate movement: "P12" = 0.
• With 2 s warning prior to gate movement: "P12" = 1.
Connect the aerial cable to terminals 33 (conductor) and 34 (braid).
6.2.4. Wired code keypad - Fig. 13
Not operational using solar power.
6.2.5. Aerial - Fig. 14
5
Comments
COMPLETE/OPENING cycle
programmable
PEDESTRIAN/CLOSING cycle
programmable
Do not change the position of
the aerial
6.2.6. Safety edge - Fig. 15
Not operational using solar power.
With autotest: programme parameter "P09" = 2.
Allows an automatic test to be carried out to check the operation of the
safety edge each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the
operating mode changes to deadman operation (a er 3 minutes).
6.2.7. Lock - Fig.16
Not operational using backup battery power supply.
6.2.8. Battery - Fig. 17
Degraded operation: speed reduced and constant (no slowdown at end lim-
it), 24 V accessories inactive (including cells), electric lock incompatible.
Life: 5 cycles/24 hrs
6.2.9. Area lighting - Fig. 18
For class I lighting, connect the earth wire to terminal 3 or 4.
The earth wire must always be longer than the live and neutral wires in
case of detachment.
Several lights may be connected provided the total power does not exceed
500 W.
6.2.10. External locking - Fig. 19
Only for a Axovia MultiPro.

7. ADVANCED PARAMETER SETTING

7.1. Navigating the parameter list

Press ...
Access and exit the parameter setting menu
Navigate the parameters and codes list:
• short press = scroll through individual parameters
• press and hold = scroll rapidly through parameters
Confirm:
• the parameter selection
• the parameter value
Increase/reduce the parameter value:
• short press = scroll through individual values
• press and hold = scroll rapidly through values
Press SET to exit the parameter setting menu.

7.2. Displaying the value of the parameters

If the display is fixed, the displayed value is the value selected for this
parameter.
If the display is flashing, the displayed value is the value which can be
selected for this parameter.
CONTROL BOX 3S io
to...
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.

Publicité

Table des Matières
loading

Table des Matières