Description Of The Various Additional Devices - SOMFY CONTROL BOX 3S io Manuel D'installation

Masquer les pouces Voir aussi pour CONTROL BOX 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Control Box 3S io

description of the various additional devices

The peripheral cables must be secured using the cable clamps supplied.
photoelectric cells (fig. 1)
Three types of connection are possible:
A: Without autotest: programme parameter "P07" = 1.
B: With autotest: programme parameter "P07" = 3.
Allows an automatic test to be carried out to check the operation of the photoelectric cells each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
C: BUS: programme parameter "P07" = 4. Auto-programming must be repeated after the cell BUS has been connected.
If cells are removed, it is essential to create the bridge between terminals 23 and 24.
It is compulsory to install photoelectric cells if:
- the automatic control device is being controlled remotely (user unable to see it),
- automatic closing is activated (P01 = 1, 3 or 4).
It is compulsory to install photoelectric cells WITH AUTOTEST (P07 = 3 or 4) if the automatic control device is being controlled by a
Tahoma control box.
Reflex photoelectric cell (Fig. 2)
Without autotest: programme parameter "P07" = 1.
With autotest: programme parameter "P07" = 2.
Allows an automatic test to be carried out to check the operation of the photoelectric cell each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
It is compulsory to install photoelectric cells WITH AUTOTEST (P07 = 2) if the automatic control device is being controlled by a Tahoma
control box.
Orange light (fig. 3)
Programme parameter "P12" according to the required operating mode:
• No warning prior to gate movement: "P12" = 0.
• With 2 s warning prior to gate movement: "P12" = 1.
Connect the aerial cable to terminals 33 (conductor) and 34 (braid).
wired code keypad (fig. 4)
Aerial (fig. 5)
Safety edge (fig. 6)
With autotest: programme parameter "P09" = 2.
Allows an automatic test to be carried out to check the operation of the safety edge each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
Lock (fig. 7)
Not operational using backup battery power.
Battery (fig. 8)
Degraded operation: speed reduced and constant (no slowdown at end limit), 24 V accessories inactive (including cells), electric door-opener incompatible.
Life: 3 cycles/24 hrs
Area lighting (fig. 9)
For class I lighting, connect the earth wire to terminal 3 or 4.
Note: The earth wire must always be longer than the live and neutral wires in case of detachment.
Several lights may be connected provided the total power does not exceed 500 W.