Télécharger Imprimer la page

Ingersoll Rand UP5 4 Installation, Exploitation Et Maintenance page 11

Publicité

Les langues disponibles

Les langues disponibles

71113.13.16
5)
Clean the mating face of the housing taking care to avoid
any particles entering the machine .
Remove the new Ingersoll Rand replacement filter from
6)
its protective package .
7)
Apply a small amount of lubricant to the filter seal .
8)
Screw the new filter down until the seal makes contact
with the housing, then hand tighten a further half turn .
9)
Start the compressor and check for leaks .
AIR FILTER ELEMENT CHANGE PROCEdURE
1)
Stop the machine, electrically isolate and vent all trapped
pressure .
2)
Unscrew the retaining cap and withdraw the old
element .
3)
Fit the new element .
4)
Replace the retaining cap .
SEPARATOR ELEMENT CHANGE PROCEdURE
1)
Stop the machine, electrically isolate and vent all trapped
pressure .
2)
Loosen separator element with the correct tool .
3)
Remove the element from the housing; place it in a
sealed bag and dispose of it safely .
4)
Clean the mating face of the housing .
5)
Remove the new Ingersoll Rand replacement element
from its protective package .
6)
Apply a small amount of lubricant to the element seal .
7)
Screw the new element down until the seal makes
contact with the housing, then hand tighten a further
half turn .
8)
Start the compressor and check for leaks .
60hz
125 psig
150 psig
210 psig
50hz
8 bar
10 bar
14 .5 bar
* "Krikit I"gauge or equal
** "Krikit II"gauge or equal
80447113 Rev.A
All manuals and user guides at all-guides.com
5hp/4kw *
New
Used
75 Lb
62 Lb
110 Lb
(34 Kg)
(28 Kg)
(50 Kg)
75 Lb
62 Lb
(34 Kg)
(28 Kg)
(41Kg)
75 Lb
62 Lb
(34 Kg)
(28 Kg)
(41Kg)
85 Lb
70 Lb
(39 Kg)
(32 Kg)
(39 Kg)
90 Lb
75 Lb
(41Kg)
(34 Kg)
(39 Kg)
90 Lb
75 Lb
100 Lb
(41Kg)
(34 Kg)
(45 Kg)
MAINTENANCE
This unit is not designed or intended to operate when
contaminated with silicone . lubricants, greases or other
items containing silicone should not be used on this
unit .
COOLER CLEANING PROCEdURE
1)
Stop the machine, electrically isolate and vent all trapped
pressure .
2)
Remove the top cover to obtain access to the cooler .
3)
Clean the cooler .
4)
Rebuild in reverse order .
BELT CHECKING ANd AdjUSTMENT PROCEdURE
Check belt tension occasionally, especially if looseness is
suspected . A quick check to determine if adjustment is
proper may be made by observing the slack side of the belt
for a slight bow when the unit is in operation .
If a slight bow is evident, the belt is usually adjusted
satisfactorily .
A belt tension measurement device can be used to determine
the tension of the belt .
Belt tensioning can be achieved by loosening the airend
anchor screws, a belt tensioning bolt is provided to aid in
moving the airend .
Follow the procedures outlined below to correctly set and
measure belt tension .
1)
Lay a straight edge across the top outer surface of the
belt drive frompulley to sheave .
At the center of the span, perpendicular to the belt, apply
pressure to the outer surface of the belt with a tension gauge .
Force the belt to the deflection indicated in the table below,
and compare the reading on the tension gauge to the figures
shown .-Belt tension
BELT TENSION
7 .5hp/5 .5kw *
New
Used
90 Lb
110 Lb
(41Kg)
(50 Kg)
90 Lb
75 Lb
110 Lb
(34 Kg)
(50 Kg)
90 Lb
75 Lb
110 Lb
(34 Kg)
(50 Kg)
85 Lb
70 Lb
110 Lb
(32 Kg)
(50 Kg)
85 Lb
70 Lb
120 Lb
(32 Kg)
(54 Kg)
80 Lb
120 Lb
(36 Kg)
(54 Kg)
CAUTION
10hp/7 .5kw *
New
Used
90 Lb
140 Lb
(41Kg)
(64 Kg)
90 Lb
140 Lb
(41Kg)
(64 Kg)
90 Lb
150 Lb
(41Kg)
(68 Kg)
90 Lb
140 Lb
(41Kg)
(64 Kg)
100 Lb
140 Lb
(45 Kg)
(64 Kg)
100 Lb
150 Lb
(45 Kg)
(68 Kg)
15hp/11kw **
New
Used
120 Lb
(54 Kg)
120 Lb
(54 Kg)
125 Lb
(57 Kg)
120 Lb
(54 Kg)
120 Lb
(54 Kg)
125 Lb
(57 Kg)
11

Publicité

loading

Ce manuel est également adapté pour:

Up5 5Up5 7Up5 11cUp6 5Up6 7Up6 10 ... Afficher tout