Installation; Air Duct (Optional) - Stiebel Eltron SHP-F 220 Premium Utilisation Et Installation

Masquer les pouces Voir aussi pour SHP-F 220 Premium:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

Installation
Minimum clearances
≥400
≥350
≥350
≥350
f Maintain the minimum clearances.
f
Material losses
!
The appliance must be positioned vertically to avoid
damage.
The appliance has height-adjustable feet.
f Level the appliance horizontally using the height-ad-
f
justable feet.
18
| SHP-F 220-300 Premium
10. Installation
≥400
You can operate the appliance in recirculation air mode or with
an air duct connection. You can have horizontal air routing (with a
side air intake and discharge), vertical air routing (with air intake
≥350
and discharge in the appliance cover) or a combination of the two,
thus ensuring flexible installation options and configurations in
the installation room. Accessories are required for the vertical air
intake and/or air discharge.

10.1 Air duct (optional)

Option: Fit the reducer to the side air connector
The side air duct connectors have a diameter of DN 200 when
≥350
delivered. Standard delivery includes reducers for the air intake
and discharge should you wish to connect an air duct with a di-
ameter of DN 160.
≥350
f Fit the reducer to the air connector by engaging the locking
f Grip the small vanes on the reducer with your fingers.
f Turn the reducer clockwise until it audibly engages.
Air duct connection
f Connect a flexible 500 cm hose to the air duct.
WARNING Injury
!
Incorrect installation can lead to serious injury or materi-
al damage. Before any work, ensure sufficient clearances
for the installation.
Handle sharp-edged components carefully.
Material losses
!
Observe the lower application limit for the appliance. The
temperature of the air discharged from the appliance may
be lower than this value. If this air is admitted into the
building, this can lead to frost damage, e.g. on water
pipes.
f
hooks on the back of the reducer in the openings provided in
the air connector.
f
f
Note
Connect the appliance and the air duct system using a
flexible method, e.g. a flexible ventilation pipe, to reduce
noise and vibrations.
f
 
The installation of a thermally insulated air hose is de-
scribed as an example.