OPERATION
Troubleshooting
Problem
Cause
The appliance reduces the
set value temporarily to the
current actual value on the in-
tegral sensor subject to the in-
take temperature and the hot
gas temperature, as required.
The air intake temperature
exceeds the upper application
limit (see "Specification / Data
table" chapter). The appli-
ance safety equipment has
responded and the appliance
has switched off automatically.
The air intake temperature
falls below the lower applica-
tion limit (see "Specification /
Data table" chapter). The
evaporator is being defrosted
intermittently.
The appliance output data are
calculated according to stand-
ard, using the intake temper-
ature specified in the data
table. Below this temperature
the appliance efficiency and
output decrease. The heat-up
time is extended.
If the water does not heat up
or the heat pump runtime is
very long, this may be due to
an excessively low intake tem-
perature.
The appliance
The compressor lockout time
is not heating
has not yet elapsed. Once the
the DHW cylin-
compressor has been switched
der, although
off, it will only be switched
the "heat
back on again after the
pump" symbol
20 minute compressor lockout
is illuminated.
time has elapsed.
The safety valve
The appliance is under mains
of the cold
water pressure. During the
water supply
heat-up process, expansion
line is dripping.
water will drip from the safety
valve.
The condensate
The surface temperature of
drain drips.
the evaporator is lower than
the dew point temperature of
the ambient air. Condensate
forms.
The room tem-
perature drops
too low.
High power
The lower the intake tempera-
consumption
ture, the lower the heat pump
efficiency.
Runtime-dependent rapid
heat-up is activated.
www.stiebel-eltron.com
Remedy
No action required. The ap-
pliance displays the "Set tem-
perature adjustment" symbol
and blocks DHW heating until
the actual temperature cap-
tured by the integral sensor is
6 K below the temporary set
temperature. DHW heating is
then re-enabled and the orig-
inally selected set tempera-
ture is again applied.
Wait for the appliance to cool
down. Call a qualified con-
tractor if the appliance does
not restart automatically.
Wait until the appliance re-
starts automatically.
Use runtime-dependent rapid
heat-up if necessary.
No action required. Use runt-
ime-dependent rapid heat-up
if necessary.
No action required.
Notify a qualified contractor if
water continues to drip when
heat-up has been completed.
The amount of condensate
depends on the humidity
level of the ambient air.
Operation of the appliance
can cause the room temper-
ature to fall by 1 to 3 °C. If
the room temperature falls
by more than 5 °C, check the
room size (see the "Specifi-
cation / Data table" chapter).
Increasing the room size by
opening a door to another
room will remedy this.
Avoid low intake tempera-
tures if at all possible.
Only activate this function if
really necessary or increase
the runtime during which the
heat pump operates alone
and the electric emergency/
booster heater is blocked via
your selected parameters.
Problem
Cause
Service/fault
See the "Fault codes" chapter. Notify a qualified contractor.
symbol is per-
manently on.
Service/fault
See the "Fault codes" chapter. It is imperative that you notify
symbol flashes
and the water
does not heat
up.
Defrost symbol
The appliance is in defrost
is shown.
mode.
The heat pump
The lower application limit
symbol is flash-
of the heat pump has been
ing.
undershot.
There is a heat demand, but
the compressor is locked out.
The electric
A temperature controller has
emergency/
switched off the electric emer-
booster heater
gency/booster heater during
symbol is flash-
rapid heat-up.
ing.
The "electric
The "runtime-dependent rapid
emergency/
heat-up" function is enabled
booster heater"
and currently in use.
symbol illu-
minates even
though the ap-
pliance is with-
in the applica-
tion limits and
"rapid heat-up"
has not been
pressed.
The electric
The electric emergency/
emergency/
booster heater lights up when
booster heater
there is a demand. The inter-
symbol is illu-
nal controller of the electric
minated but the
emergency/booster heater
electric emer-
may have ended electric
gency/booster
heating. A possible cause
heater is not
may be a fault in the electric
operational.
emergency/booster heater. A
possible cause may be that the
high limit safety cut-out has
responded.
Remedy
a qualified contractor quickly.
A flashing "service/fault"
symbol indicates that a fault
has occurred and the heat
pump is no longer heating.
No action required.
No action required. The
electric emergency/booster
heater takes over the DHW
heating.
No action required. The com-
pressor restarts automatically
after the compressor lockout
time has elapsed. The com-
pressor lockout time lasts
20 minutes once the com-
pressor has been shut down.
The symbol stops flashing
automatically.
No action required. The ap-
pliance continues the quick
heat-up process using the
heat pump. The symbol stops
flashing when the controller
re-enables the electric emer-
gency/booster heater. The
symbol extinguishes when
the temperature throughout
the DHW cylinder reaches the
set temperature of 65 °C.
No action required.
Have a qualified contractor
check whether the controller
of the electric emergency/
booster heater is set correct-
ly. The controller must be
turned fully clockwise. Have a
qualified contractor check the
high limit safety cut-out.
SHP-F 220-300 Premium |
13