INSTALLATION
Installation
Material losses
!
The integration of an external heat generator via the "heat
source flow" connection must not result in the application
limits being exceeded (see chapter "Specification / Data
table").
The connected external heat generator cannot be con-
trolled by the appliance. The external heat generator
must be controlled externally. Any possibility of exceed-
ing the maximum permissible DHW temperature in the
cylinder (as given in chapter "Specification/Data table")
must be prevented.
Material losses
!
Carry out all installation work in accordance with regula-
tions. In Germany, to comply with heating system regula-
tions, an external heat generator must be connected with
a diaphragm expansion vessel and a safety valve between
the external heat generator and the DHW cylinder.
External heat generators may only be connected with DHW priority
control. As part of this, the cylinder temperature must be captured
with an electronic temperature sensor with safety low voltage.
The DHW cylinder of the appliance allows the temperature sensor
to be positioned at one of two different heights in the cylinder.
Using the sensor sleeve in the upper third of the cylinder enables
later DHW heating by means of the external heat generator, than
the lower sensor position.
Heating circuit oxygen diffusion
Material losses
!
Avoid open vented heating systems and underfloor heat-
ing systems with plastic pipes which are permeable to
oxygen.
In underfloor heating systems with plastic pipes that are per-
meable to oxygen and in open vented heating systems, oxygen
diffusion may lead to corrosion on the steel components of the
heating system (e.g. on the indirect coil of the DHW cylinder, on
buffer cylinders, steel radiators or steel pipes).
Material losses
!
The products of corrosion (e.g. rusty sludge) can set-
tle in the heating system components, which may re-
sult in a lower output or fault shutdowns due to reduced
cross-sections.
Solar circuit oxygen diffusion
Material losses
!
Avoid open vented solar thermal systems and plastic
pipes which are permeable to oxygen.
With plastic pipes that are permeable to oxygen, oxygen diffusion
can cause corrosion on the steel components of the solar thermal
system (e.g. on the indirect coil of the DHW cylinder).
www.stiebel-eltron.com
Water quality, solar circuit
Material losses
!
A glycol-water mixture up to 60 % is permissible for
the solar circuit, provided only dezincification-resistant
metals, glycol-resistant gaskets and diaphragm expan-
sion vessels suitable for glycol are used throughout the
installation.

10.4 Condensate drain

Install a condensate drain hose in order to remove the condensate
which forms.
f Connect the condensate drain bend included in the standard
f
delivery to the condensate drain connection.
f Connect a condensate drain hose to the condensate drain
f
bend.
Material losses
!
Ensure condensate cannot back up.
f Use a condensate drain hose with a diameter great-
f
er than the diameter of the condensate drain bend.
f Ensure the condensate drain hose is not kinked.
f
f Route the condensate drain hose with a continuous
f
fall.
The condensate drain must be open to atmosphere.
f Use a suitable condensate pump if there is insufficient fall.
f
Take the building characteristics into account.

10.5 Power supply

WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with national and regional regulations.
WARNING Electrocution
If the appliance is permanently connected to the power
supply, ensure that the appliance can be separated from
the power supply by an isolator that disconnects all poles
with at least 3 mm contact separation. Contactors, mains
isolators or fuses can be used for this.
WARNING Electrocution
f Observe the safety measures to prevent contact
f
with dangerous 'live' currents.
WARNING Electrocution
Coming into contact with 'live' components presents a
threat to life. Disconnect the appliance from the power
supply before carrying out work on the control panel.
Prevent the power supply from being switched on while
you are working on the system.
WARNING Electrocution
Insufficient earthing can lead to electrocution. Ensure
the appliance is earthed according to locally applicable
requirements.
SHP-F 220-300 Premium |