iNSTallaTiON

Safety

iNSTallaTiON
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
Material losses
!
Observe the maximum inlet temperature. Higher tem-
peratures may damage the appliance. You can limit the
maximum inlet temperature by installing a central ther-
mostatic valve.
WARNING Electrocution
This appliance contains capacitors which are discharged
when disconnected from the power supply. The capacitor
discharge voltage may briefly exceed 60 V DC.
6.2

Shower operation

CAUTION Burns
f When supplying a shower, set the internal anti-
scalding protection to 55 °C or less; see chapter
"Commissioning / Preparations".
CAUTION Burns
If operating with preheated water, e.g. if using a solar
thermal system, observe the following information:
The DHW temperature may exceed the set temperature
or a set temperature limit.
f In this case, limit the temperature with an upstream
central thermostatic valve.
6.3

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
- The protection rating IP 25 (hoseproof) is only guaranteed
with a properly fitted cable grommet and the use of counter-
sunk screws Ø 4.5 mm with a max. head diameter of 9 mm.
- The electrical resistivity of the water must not fall below that
stated on the type plate. In a linked water network, take into
consideration the lowest electrical resistivity of the water.
Your water supply utility will advise you of the electrical re-
sistivity or conductivity of the water in your area.
6
| DCE-S Plus
7.

Appliance description

7.1

Standard delivery

The following are delivered with the appliance:
- 2 x 45° twin connectors
- 2 flat gaskets
- 2 O-rings
- Cable grommet
- Strainer
- Flow limiter
- Jumper for anti-scalding protection, attached
- Jumper for output changeover, attached
7.2

Accessories

Installation kit for water installation on unfinished walls
(200016 - UP-Kit EU)
The installation kit for water installation on unfinished walls con-
tains:
- 2 x grommets to seal the apertures in the appliance back
panel.
- Strainer with sealed edge for installation on the 45° twin
connector.
- Flat gasket
8.

Preparation

8.1

Installation site

Material losses
!
Install the appliance in a room that is free from the risk
of frost.
f Always install the appliance vertically and near the draw-off
point.
The appliance is suitable for undersink and oversink installation.