alternative installation methods
12.2 Electrical connection from below on unfinished
walls
1 Cable grommet
f Break out the required aperture in the back panel for the
power cable (for positions, see chapter "Specification / Di-
mensions and connections"). Deburr any sharp edges with a
file.
f Cut a hole in the cable grommet to fit the selected connecting
cable. Fit the cable grommet.
f Install the appliance and connect the power cable to the
mains terminal as described in chapter "Installation / Stand-
ard installation on finished walls".
12.3 Electrical connection with short power cable
If the power cable is not quite long enough, you can install the
mains terminal in the appliance a little closer to the aperture.
1 Cable grommet
f Reposition the mains terminal from the top to the bottom. To
do so, unclip the mains terminal by pushing it firmly to the
left and pulling it forwards. Clip the mains terminal in at the
bottom by pushing it inwards and to the left until it clicks
into place.
12.4 Electrical connection from the side on finished
walls
f Cut and break out the required aperture in the appliance
back panel and appliance cover for the power cable (for po-
sitions, see chapter "Specification / Dimensions and connec-
tions"). Deburr any sharp edges with a file.
f Install the appliance and connect the power cable to the
mains terminal as described in chapter "Installation / Stand-
ard installation on finished walls".
www.stiebel-eltron.com

12.5 Water installation on unfinished walls

You will need the appropriate accessories to carry out the in-
stallation. The installation kit for water installation on unfinished
walls contains:
- 2 x grommets to seal the apertures in the appliance back
panel.
- Strainer with sealed edge for installation on the 45° twin
connector.
- Flat gasket
In addition, you will need the flow limiter included in the appliance
standard delivery.
Preparation
1
f Insert and seal the 45° twin connectors.
To break out the apertures in the appliance back panel, you will
need to remove the function module from the back panel.
1
f Undo the screw and disengage the locking tab.
f Push the function module on the back panel gently
backwards.
f Remove the function module from the appliance back panel
by pulling it slightly forwards and lifting it off.
f Push/break out the required apertures for the water connec-
tions in the back panel from behind (for positions, see chap-
ter "Specification / Dimensions and connections"). Deburr any
sharp edges with a file.
3.
1.
2.
4.
5.